CVE-2023-37196
https://notcve.org/view.php?id=CVE-2023-37196
A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access unauthorized content, change, or delete content, or perform unauthorized actions when tampering with the alert settings of endpoints on DCE. • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-01.pdf • CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') •
CVE-2023-25555
https://notcve.org/view.php?id=CVE-2023-25555
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow a user that knows the credentials to execute unprivileged shell commands on the appliance over SSH. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior) • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-045-02.pdf • CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') •
CVE-2023-25553
https://notcve.org/view.php?id=CVE-2023-25553
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists on a DCE endpoint through the logging capabilities of the webserver. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior) • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-045-02.pdf • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •
CVE-2023-25551
https://notcve.org/view.php?id=CVE-2023-25551
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists on a DCE file upload endpoint when tampering with parameters over HTTP. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior) • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-045-02.pdf • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •
CVE-2023-25550
https://notcve.org/view.php?id=CVE-2023-25550
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows remote code execution via the “hostname” parameter when maliciously crafted hostname syntax is entered. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior) • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-045-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-045-02.pdf • CWE-94: Improper Control of Generation of Code ('Code Injection') •