Page 2 of 8 results (0.002 seconds)

CVSS: 8.8EPSS: 0%CPEs: 3EXPL: 0

A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause manipulation of dashboard files in the IGSS project report directory, when an attacker sends specific crafted messages to the Data Server TCP port, this could lead to remote code execution when a victim eventually opens a malicious dashboard file. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior). This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric IGSS. Authentication is not required to exploit this vulnerability. The specific flaw exists within the IGSSdataServer process, which listens on TCP port 12401 by default. The issue results from the exposure of a dangerous function. • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-073-04.pdf • CWE-345: Insufficient Verification of Data Authenticity •

CVSS: 8.8EPSS: 0%CPEs: 3EXPL: 0

A CWE-20: Improper Input Validation vulnerability exists in Custom Reports that could cause a macro to be executed, potentially leading to remote code execution when a user opens a malicious report file planted by an attacker. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior). This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric IGSS. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the openReport function. The issue results from the lack of proper input validation. • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-073-04.pdf • CWE-20: Improper Input Validation •

CVSS: 6.5EPSS: 0%CPEs: 3EXPL: 0

A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause access to delete files in the IGSS project report directory, this could lead to loss of data when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior). This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Schneider Electric IGSS. Authentication is not required to exploit this vulnerability. The specific flaw exists within the IGSSdataServer process, which listens on TCP port 12401 by default. The issue results from the exposure of a dangerous function. • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-073-04.pdf • CWE-345: Insufficient Verification of Data Authenticity •