Page 2 of 13 results (0.005 seconds)

CVSS: 9.1EPSS: 0%CPEs: 63EXPL: 0

Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller. Se presenta una vulnerabilidad de Omisión de Autenticación por Spoofing en EcoStruxure Control Expert (todas las versiones anteriores a V15.0 SP1, incluyendo todas las versiones de Unity Pro), EcoStruxure Control Expert versión V15.0 SP1, EcoStruxure Process Expert (todas las versiones, incluyendo todas las versiones de EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (todas las versiones), Modicon M580 CPU (todas las versiones - números de parte BMEP* y BMEH*), Modicon M340 CPU (todas las versiones - números de parte BMXP34*), que podría causar un acceso no autorizado en modo de lectura y escritura al controlador mediante el spoofing de la comunicación Modbus entre el software de ingeniería y el controlador • http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01 • CWE-290: Authentication Bypass by Spoofing •

CVSS: 7.5EPSS: 0%CPEs: 32EXPL: 0

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller. Una CWE-754: Se presenta una vulnerabilidad de Comprobación Inapropiada de Condiciones Inusuales o Excepcionales en Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (consulte las notificaciones de seguridad para las versiones afectadas), que podría causar una denegación de servicio cuando una petición Read Physical Memory especialmente diseñada a través de Modbus es enviada hacia el controlador • https://www.se.com/ww/en/download/document/SEVD-2020-343-08 • CWE-754: Improper Check for Unusual or Exceptional Conditions •

CVSS: 7.5EPSS: 0%CPEs: 40EXPL: 0

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller. Una CWE-754: Se presenta una vulnerabilidad de Comprobación Inapropiada de Condiciones Inusuales o Excepcionales en Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum y Modicon Premium (consulte las notificaciones de seguridad para las versiones afectadas), que podría causar una denegación de servicio cuando una petición Read Physical Memory especialmente diseñada a través de Modbus es enviada hacia el controlador • https://www.se.com/ww/en/download/document/SEVD-2020-343-08 • CWE-754: Improper Check for Unusual or Exceptional Conditions •

CVSS: 7.5EPSS: 0%CPEs: 38EXPL: 0

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller. Una CWE-754: Se presenta una vulnerabilidad de Comprobación Inapropiada de Condiciones Inusuales o Excepcionales en Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum y Modicon Premium (consulte las notificaciones de seguridad para las versiones afectadas), que podría causar una denegación de servicio cuando una petición Read Physical Memory especialmente diseñada a través de Modbus es enviada hacia el controlador • https://www.se.com/ww/en/download/document/SEVD-2020-343-08 • CWE-754: Improper Check for Unusual or Exceptional Conditions •

CVSS: 7.5EPSS: 0%CPEs: 47EXPL: 0

Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control Expert and the M340 and M580 controllers. Existe una vulnerabilidad de Autorización Incorrecta en EcoStruxure Control Expert (todas las versiones anteriores a la 14.1 Hot Fix), Unity Pro (todas las versiones), Modicon M340 (todas las versiones anteriores a la V3.20) , y Modicon M580 (todas las versiones anteriores a la V3.10), que podría causar un bypass del proceso de autenticación entre EcoStruxure Control Expert y los controladores M340 y M580 • https://www.se.com/ww/en/download/document/SEVD-2019-344-02 • CWE-863: Incorrect Authorization •