CVSS: 9.1EPSS: 0%CPEs: 63EXPL: 0

Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller. Se presenta una vulnerabilidad de Omisión de Autenticación por Spoofing en EcoStruxure Control Expert (todas las versiones anteriores a V15.0 SP1, incluyendo todas las versiones de Unity Pro), EcoStruxure Control Expert versión V15.0 SP1, EcoStruxure Process Expert (todas las versiones, incluyendo todas las versiones de EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (todas las versiones), Modicon M580 CPU (todas las versiones - números de parte BMEP* y BMEH*), Modicon M340 CPU (todas las versiones - números de parte BMXP34*), que podría causar un acceso no autorizado en modo de lectura y escritura al controlador mediante el spoofing de la comunicación Modbus entre el software de ingeniería y el controlador • http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01 • CWE-290: Authentication Bypass by Spoofing •

CVSS: 7.8EPSS: 0%CPEs: 36EXPL: 0

A CWE-119 Buffer Errors vulnerability exists in Modicon M580 CPU - BMEP582040, all versions before V2.90, and Modicon Ethernet Module BMENOC0301, all versions before V2.16, which could cause denial of service on the FTP service of the controller or the Ethernet BMENOC module when it receives a FTP CWD command with a data length greater than 1020 bytes. A power cycle is then needed to reactivate the FTP service. Una CWE-119: Existe una vulnerabilidad de Errores de Búfer en la CPU M580 - BMEP582040 de Modicon , todas las versiones anteriores a la V2.90, y el módulo Ethernet BMENOC0301 de Modicon, todas las versiones anteriores a la V2.16, lo que podría causar la denegación de servicio en el servicio FTP del controlador o Módulo Ethernet BMENOC cuando recibe un comando CWD de FTP con una longitud de datos superior a 1020 bytes. Se necesita entonces un ciclo de energía para reactivar el servicio FTP. • https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-190-03 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •

CVSS: 6.8EPSS: 0%CPEs: 41EXPL: 0

CWE-119: Buffer errors vulnerability exists in Modicon M580 with firmware prior to V2.50, Modicon M340 with firmware prior to V3.01, BMxCRA312xx with firmware prior to V2.40, All firmware versions of Modicon Premium and 140CRA312xxx when sending a specially crafted Modbus packet, which could cause a denial of service to the device that would force a restart to restore availability. CWE-119: Existe una vulnerabilidad de errores de búfer en Modicon M580 con firmware anterior a V2.50, Modicon M340 con firmware anterior a V3.01, BMxCRA312xx con firmware anterior a V2.40 y todas las versiones de firmware de Modicon Premium y 140CRA312xxx al enviar un paquete Modbus especialmente creado, que podría generar una Denegación de Servicio al dispositivo que forzaría un reinicio para restaurar la disponibilidad. • https://www.schneider-electric.com/en/download/document/SEVD-2019-134-10 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •

CVSS: 7.5EPSS: 0%CPEs: 38EXPL: 0

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists which could cause a possible Denial of Service when specific Modbus frames are sent to the controller in the products: Modicon M340 - firmware versions prior to V3.01, Modicon M580 - firmware versions prior to V2.80, All firmware versions of Modicon Quantum and Modicon Premium. Una CWE-754: Existe una vulnerabilidad de Comprobación Inapropiada para condiciones inusuales o excepcionales, que podría generar una posible Denegación de Servicio cuando se envían tramas Modbus específicas hacia el controlador en los productos: Modicon M340 - versiones de firmware anteriores a la V3.01, Modicon M580 - versiones de firmware anteriores a V2.80, y todas las versiones de firmware de Modicon Quantum y Modicon Premium. • http://www.securityfocus.com/bid/109004 https://www.schneider-electric.com/en/download/document/SEVD-2019-134-05 • CWE-754: Improper Check for Unusual or Exceptional Conditions •