Page 2 of 21 results (0.011 seconds)

CVSS: 9.8EPSS: 3%CPEs: 8EXPL: 1

22 May 2019 — A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by overwriting configuration settings of the controller over Modbus. Una CWE-284: Vulnerabilidad de Control de Acceso inapropiado en todas las versiones de Modicon M580, Modicon M340, Modicon Quantum y Modicon Premium, podría generar una ejecución remota de código al sobrescribir en los ajustes de configuración del controlad... • https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11 • CWE-306: Missing Authentication for Critical Function •

CVSS: 7.5EPSS: 0%CPEs: 8EXPL: 1

22 May 2019 — A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of service when writing sensitive application variables to the controller over Modbus. Una CWE-248: Vulnerabilidad de Excepción no Detectada en todas las versiones de Modicon M580, Modicon M340, Modicon Quantum y Modicon Premium, que podría generar una posible Denegación de Servicio cuando se escriben variables de aplicación sensibles ... • https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11 • CWE-755: Improper Handling of Exceptional Conditions •

CVSS: 7.5EPSS: 0%CPEs: 8EXPL: 1

22 May 2019 — A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading variables in the controller using Modbus. Una CWE-200: Existe una vulnerabilidad de Exposición de Información en todas las versiones de Modicon M580, Modicon M340, Modicon Quantum y Modicon Premium, que podría generar la divulgación de información SNMP cuando se leen variables en el controlador usando pr... • https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11 •

CVSS: 7.5EPSS: 0%CPEs: 8EXPL: 1

22 May 2019 — A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible Denial of Service when writing out of bounds variables to the controller over Modbus. CWE-248: Existe una vulnerabilidad de Excepción no Detectada en todas las versiones de Modicon M580, Modicon M340, Modicon Quantum y Modicon Premium, que podría generar una posible Denegación de Servicio cuando se escriben variables fuera de límites hacia el... • https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11 • CWE-754: Improper Check for Unusual or Exceptional Conditions •

CVSS: 7.5EPSS: 0%CPEs: 8EXPL: 1

22 May 2019 — A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of Service when writing invalid memory blocks to the controller over Modbus. Una CWE-248: Existe una vulnerabilidad de Excepción no Detectada en todas las versiones de Modicon M580, Modicon M340, Modicon Quantum y Modicon Premium, que podría generar una posible Denegación de Servicio cuando se escriben bloques de memoria no válidos hac... • https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11 • CWE-754: Improper Check for Unusual or Exceptional Conditions •

CVSS: 7.5EPSS: 0%CPEs: 8EXPL: 2

22 May 2019 — A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a Denial of Service when sending invalid breakpoint parameters to the controller over Modbus Una CWE-248: Existe una vulnerabilidad de Excepción no Detectada en todas las versiones de Modicon M580, Modicon M340, Modicon Quantum y Modicon Premium, que podría generar una Denegación de Servicio al enviar parámetros Breakpoint no válidos hacia el controlador... • https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11 • CWE-754: Improper Check for Unusual or Exceptional Conditions •

CVSS: 7.5EPSS: 1%CPEs: 8EXPL: 2

22 May 2019 — A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a denial of Service when sending invalid debug parameters to the controller over Modbus. Una CWE-248: Existe una vulnerabilidad de Excepción no Detectada en todas las versiones de Modicon M580, Modicon M340, Modicon Quantum y Modicon Premium, que podría generar una Denegación de Servicio al enviar parámetros Debug no válidos hacia el controlador mediante... • https://github.com/yanissec/CVE-2018-7854 • CWE-754: Improper Check for Unusual or Exceptional Conditions •

CVSS: 7.5EPSS: 0%CPEs: 8EXPL: 1

22 May 2019 — A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when reading invalid physical memory blocks in the controller over Modbus Una CWE-248: Existe una vulnerabilidad de Excepción no Detectada en todas las versiones de Modicon M580, Modicon M340, Modicon Quantum y Modicon Premium, que podría generar una Denegación de Servicio cuando se leen bloques de memoria física no válidos en el contr... • https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11 • CWE-754: Improper Check for Unusual or Exceptional Conditions •

CVSS: 7.5EPSS: 13%CPEs: 8EXPL: 2

22 May 2019 — A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading files from the controller over Modbus CWE-200: Existe una vulnerabilidad de Exposición de Información en todas las versiones de Modicon M580, Modicon M340, Modicon Quantum y Modicon Premium, que podría generar la divulgación de información SNMP cuando se leen archivos desde el controlador sobre protocolo... • https://github.com/yanissec/CVE-2018-7848 • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •

CVSS: 7.5EPSS: 0%CPEs: 38EXPL: 0

22 May 2019 — A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists which could cause a possible Denial of Service when specific Modbus frames are sent to the controller in the products: Modicon M340 - firmware versions prior to V3.01, Modicon M580 - firmware versions prior to V2.80, All firmware versions of Modicon Quantum and Modicon Premium. Una CWE-754: Existe una vulnerabilidad de Comprobación Inapropiada para condiciones inusuales o excepcionales, que podría generar una posible Denega... • http://www.securityfocus.com/bid/109004 • CWE-754: Improper Check for Unusual or Exceptional Conditions •