Page 2 of 10 results (0.008 seconds)

CVSS: 7.5EPSS: 0%CPEs: 26EXPL: 0

A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions < V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions < V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions). A remote attacker could use specially crafted packets sent to port 443/TCP to upload, download or delete files in certain parts of the file system. Se ha identificado una vulnerabilidad en todos los demás tipos de dispositivos SIPROTEC 5 con variantes de CPU CP300 y CP100 y los respectivos módulos de comunicación Ethernet (todas las versiones), software de ingeniería DIGSI 5 (todas las versiones anteriores a la versión V7.90), tipos de dispositivos SIPROTEC 5 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 y 7VE85 y CPU con variantes CP300 y CP100 los respectivos módulos de comunicación Ethernet (todas las versiones anteriores a la versión V7.90), tipos de dispositivos SIPROTEC 5 7SS85 y 7KE85 (todas las versiones anteriores a la versión V8.01), tipos de dispositivos SIPROTEC 5 con variantes de CP200 y los respectivos módulos de comunicación Ethernet (todas las versiones). Un atacante remoto podría usar paquetes especialmente diseñados enviados al puerto 443/TCP para cargar, descargar o eliminar archivos en ciertas partes del sistema de archivos • https://cert-portal.siemens.com/productcert/pdf/ssa-899560.pdf • CWE-434: Unrestricted Upload of File with Dangerous Type CWE-552: Files or Directories Accessible to External Parties •

CVSS: 7.5EPSS: 0%CPEs: 29EXPL: 0

A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions < V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions < V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.59), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.59). Specially crafted packets sent to port 443/TCP could cause a Denial of Service condition. Se ha identificado una vulnerabilidad en todos los demás tipos de dispositivos SIPROTEC 5 con variantes de CPU CP300 y CP100 y los respectivos módulos de comunicación Ethernet (todas las versiones), software de ingeniería DIGSI 5 (Todas las versiones anteriores a la versión V7.90), tipos de dispositivos SIPROTEC 5 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 y 7VE85 con variantes de CPU CP300 y CP100 los respectivos módulos de comunicación Ethernet (Todas las versiones anteriores a la versión V7.90), tipos de dispositivos SIPROTEC 5 7SS85 y 7KE85 (Todas las versiones anteriores a la versión V8.01), tipos de dispositivos SIPROTEC 5 con variantes CPU CP200 y los respectivos módulos de comunicación Ethernet (Todas las versiones anteriores a la versión V7.59), los relés SIPROTEC 5 con las variantes de CPU CP200 y los respectivos módulos de comunicación Ethernet (Todas las versiones anteriores a la versión V7.59). Los paquetes especialmente diseñados enviados al puerto 443/TCP podrían causar una condición de denegación de servicio • https://cert-portal.siemens.com/productcert/pdf/ssa-899560.pdf • CWE-248: Uncaught Exception •

CVSS: 5.9EPSS: 0%CPEs: 34EXPL: 0

A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.35), Firmware variant MODBUS TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions), Firmware variant Profinet IO for EN100 Ethernet module (All versions), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.82), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. • https://cert-portal.siemens.com/productcert/pdf/ssa-104088.pdf •

CVSS: 7.8EPSS: 0%CPEs: 33EXPL: 0

A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.33), Firmware variant PROFINET IO for EN100 Ethernet module (All versions), Firmware variant Modbus TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions < V1.22), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.80), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. • https://cert-portal.siemens.com/productcert/pdf/ssa-325546.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-635129.pdf https://www.securityfocus.com/bid/106221 • CWE-20: Improper Input Validation •

CVSS: 7.8EPSS: 0%CPEs: 33EXPL: 0

A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.33), Firmware variant PROFINET IO for EN100 Ethernet module (All versions), Firmware variant Modbus TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions < V1.22). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the EN100 communication module if oscillographs are running. A manual restart is required to recover the EN100 module functionality. Successful exploitation requires an attacker with network access to send multiple packets to the EN100 module. As a precondition the IEC 61850-MMS communication needs to be activated on the affected EN100 modules. • https://cert-portal.siemens.com/productcert/pdf/ssa-325546.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-635129.pdf https://www.securityfocus.com/bid/106221 • CWE-20: Improper Input Validation •