Page 2 of 32 results (0.004 seconds)

CVSS: 7.8EPSS: 0%CPEs: 3EXPL: 0

A vulnerability has been identified in JT Open (All versions < V11.1.1.0), JT Utilities (All versions < V13.1.1.0), Solid Edge (All versions < V2023). The Jt1001.dll contains a memory corruption vulnerability while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19078) This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Solid Edge Viewer. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of JT files. • https://cert-portal.siemens.com/productcert/pdf/ssa-936212.pdf • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer CWE-787: Out-of-bounds Write •

CVSS: 7.8EPSS: 0%CPEs: 2EXPL: 0

A vulnerability has been identified in JT Utilities (All versions < V12.8.1.1), JTTK (All versions < V10.8.1.1). JTTK library in affected products is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-15055, ZDI-CAN-14915, ZDI-CAN-14865) Se ha identificado una vulnerabilidad en JT Utilities (Todas las versiones anteriores a V12.8.1.1), JTTK (Todas las versiones anteriores a V10.8.1.1). La biblioteca JTTK en los productos afectados es vulnerable a una lectura fuera de límites más allá del final de un búfer asignado al analizar archivos JT. • https://cert-portal.siemens.com/productcert/pdf/ssa-396621.pdf • CWE-125: Out-of-bounds Read •

CVSS: 7.8EPSS: 0%CPEs: 2EXPL: 0

A vulnerability has been identified in JT Utilities (All versions < V12.8.1.1), JTTK (All versions < V10.8.1.1). JTTK library in affected products contains an out of bounds write past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14830) Se ha identificado una vulnerabilidad en JT Utilities (Todas las versiones anteriores a V12.8.1.1), JTTK (Todas las versiones anteriores a V10.8.1.1). La biblioteca JTTK en los productos afectados contiene una escritura fuera de límites más allá del final de una estructura asignada mientras son analizados archivos JT especialmente diseñados. • https://cert-portal.siemens.com/productcert/pdf/ssa-396621.pdf • CWE-787: Out-of-bounds Write •

CVSS: 4.3EPSS: 0%CPEs: 2EXPL: 0

A vulnerability has been identified in JT Utilities (All versions < V13.0.3.0), JTTK (All versions < V11.0.3.0). JTTK library in affected products is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-14843, ZDI-CAN-15051) Se ha identificado una vulnerabilidad en JT Utilities (Todas las versiones anteriores a V13.0.3.0), JTTK (Todas las versiones anteriores a V11.0.3.0). La biblioteca JTTK en los productos afectados es vulnerable a una lectura fuera de límites más allá del final de un búfer asignado al analizar archivos JT. • https://cert-portal.siemens.com/productcert/pdf/ssa-352143.pdf • CWE-125: Out-of-bounds Read •

CVSS: 7.8EPSS: 0%CPEs: 2EXPL: 0

A vulnerability has been identified in JT Utilities (All versions < V13.0.3.0), JTTK (All versions < V11.0.3.0). JTTK library in affected products contains a use-after-free vulnerability that could be triggered while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-14911) Se ha identificado una vulnerabilidad en JT Utilities (Todas las versiones anteriores a V13.0.3.0), JTTK (Todas las versiones anteriores a V11.0.3.0). La biblioteca JTTK de los productos afectados contiene una vulnerabilidad de uso de memoria previamente liberada que podría desencadenarse al analizar archivos JT especialmente diseñados. • https://cert-portal.siemens.com/productcert/pdf/ssa-352143.pdf • CWE-416: Use After Free •