![](/assets/img/cve_300x82_sin_bg.png)
CVE-2022-39156 – Siemens Simcenter Femap X_T File Parsing Out-Of-Bounds Read Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2022-39156
13 Sep 2022 — A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an... • https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf • CWE-125: Out-of-bounds Read •
![](/assets/img/cve_300x82_sin_bg.png)
CVE-2022-39154 – Siemens Simcenter Femap X_T File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2022-39154
13 Sep 2022 — A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an all... • https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf • CWE-787: Out-of-bounds Write •
![](/assets/img/cve_300x82_sin_bg.png)
CVE-2022-39155 – Siemens Simcenter Femap X_T File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2022-39155
13 Sep 2022 — A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an all... • https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf • CWE-787: Out-of-bounds Write •
![](/assets/img/cve_300x82_sin_bg.png)
CVE-2022-39153 – Siemens Simcenter Femap X_T File Parsing Out-Of-Bounds Read Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2022-39153
13 Sep 2022 — A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an... • https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf • CWE-125: Out-of-bounds Read •
![](/assets/img/cve_300x82_sin_bg.png)
CVE-2022-39152 – Siemens Simcenter Femap X_T File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2022-39152
13 Sep 2022 — A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an all... • https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf • CWE-787: Out-of-bounds Write •
![](/assets/img/cve_300x82_sin_bg.png)
CVE-2022-39151 – Siemens Simcenter Femap X_T File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2022-39151
13 Sep 2022 — A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an all... • https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf • CWE-787: Out-of-bounds Write •
![](/assets/img/cve_300x82_sin_bg.png)
CVE-2022-39150 – Siemens Simcenter Femap X_T File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2022-39150
13 Sep 2022 — A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an all... • https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf • CWE-787: Out-of-bounds Write •
![](/assets/img/cve_300x82_sin_bg.png)
CVE-2022-39148 – Siemens Simcenter Femap X_T File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2022-39148
13 Sep 2022 — A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an all... • https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf • CWE-787: Out-of-bounds Write •
![](/assets/img/cve_300x82_sin_bg.png)
CVE-2022-39149 – Siemens Simcenter Femap X_T File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2022-39149
13 Sep 2022 — A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an all... • https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf • CWE-787: Out-of-bounds Write •
![](/assets/img/cve_300x82_sin_bg.png)
CVE-2022-39147 – Siemens Simcenter Femap X_T File Parsing Uninitialized Pointer Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2022-39147
13 Sep 2022 — A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application is vulnerable to uninitialized pointer access while pa... • https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf • CWE-824: Access of Uninitialized Pointer •