Page 2 of 20 results (0.004 seconds)

CVSS: 7.5EPSS: 0%CPEs: 26EXPL: 0

A vulnerability has been identified in SCALANCE X200-4P IRT, SCALANCE X201-3P IRT, SCALANCE X201-3P IRT PRO, SCALANCE X202-2IRT, SCALANCE X202-2P IRT, SCALANCE X202-2P IRT PRO, SCALANCE X204-2, SCALANCE X204-2FM, SCALANCE X204-2LD, SCALANCE X204-2LD TS, SCALANCE X204-2TS, SCALANCE X204IRT, SCALANCE X204IRT PRO, SCALANCE X206-1, SCALANCE X206-1LD, SCALANCE X208, SCALANCE X208PRO, SCALANCE X212-2, SCALANCE X212-2LD, SCALANCE X216, SCALANCE X224, SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XF201-3P IRT, SCALANCE XF202-2P IRT, SCALANCE XF204, SCALANCE XF204-2, SCALANCE XF204-2BA IRT, SCALANCE XF204IRT, SCALANCE XF206-1, SCALANCE XF208, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIMATIC CP 343-1 Advanced, SIMATIC CP 442-1 RNA, SIMATIC CP 443-1, SIMATIC CP 443-1, SIMATIC CP 443-1 Advanced, SIMATIC CP 443-1 RNA, SIMATIC RF180C, SIMATIC RF182C, SIPLUS NET CP 343-1 Advanced, SIPLUS NET CP 443-1, SIPLUS NET CP 443-1 Advanced, SIPLUS NET SCALANCE X308-2. The VxWorks-based Profinet TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service. Se ha identificado una vulnerabilidad en SCALANCE X200-4P IRT, SCALANCE X201-3P IRT, SCALANCE X201-3P IRT PRO, SCALANCE X202-2IRT, SCALANCE X202-2P IRT, SCALANCE X202-2P IRT PRO, SCALANCE X204-2, SCALANCE X204-2FM, SCALANCE X204-2LD, SCALANCE X204-2LD TS, SCALANCE X204-2TS, SCALANCE X204IRT, SCALANCE X204IRT PRO, SCALANCE X206-1, SCALANCE X206-1LD, SCALANCE X208, SCALANCE X208PRO, SCALANCE X212-2, SCALANCE X212-2LD, SCALANCE X216, SCALANCE X224, SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, revestido), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, revestido), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, revestido), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, revestido), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, revestido), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, revestido), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, revestido), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, revestido), SCALANCE X307-3 SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XF201-3P IRT, SCALANCE XF202-2P IRT, SCALANCE XF204, SCALANCE XF204-2, SCALANCE XF204-2BA IRT, SCALANCE XF204IRT, SCALANCE XF206-1, SCALANCE XF208, SCALANCE XR324-12M (230V, puertos en la parte delantera), SCALANCE XR324-12M (230V, puertos en la parte delantera), SCALANCE XR324-12M (230V, puertos en la parte trasera), SCALANCE XR324-12M (230V, puertos en la parte trasera), SCALANCE XR324-12M (24V, puertos en la parte delantera) SCALANCE XR324-12M (24V, puertos en la parte trasera), SCALANCE XR324-12M (24V, puertos en la parte trasera), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, puertos en la parte delantera), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, puertos en la parte delantera), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, puertos en la parte trasera), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, puertos en la parte trasera), SCALANCE XR324-4M EEC (24V, puertos en la parte delantera), SCALANCE XR324-4M EEC (24V, puertos en la parte delantera), SCALANCE XR324-4M EEC (24V, puertos en la parte trasera), SCALANCE XR324-4M EEC (24V, puertos en la parte trasera), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, puertos en la parte delantera), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, puertos en la parte delantera), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, puertos en la parte trasera), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, puertos en la parte trasera), SCALANCE XR324-4M EEC (2x 24V, puertos en la parte delantera), SCALANCE XR324-4M EEC (2x 24V, puertos en la parte delantera), SCALANCE XR324-4M EEC (2x 24V, puertos en la parte trasera), SCALANCE XR324-4M EEC (2x 24V, puertos en la parte trasera), SCALANCE XR324-4M PoE (230V, puertos en la parte delantera), SCALANCE XR324-4M PoE (230V, puertos en la parte trasera), SCALANCE XR324-4M PoE (24V, puertos en la parte delantera), SCALANCE XR324-4M PoE (24V, puertos en la parte trasera), SCALANCE XR324-4M PoE TS (24V, puertos en la parte delantera), SIMATIC CP 343-1 Advanced, SIMATIC CP 442-1 RNA, SIMATIC CP 443-1, SIMATIC CP 443-1 Advanced, SIMATIC CP 443-1 RNA, SIMATIC RF180C, SIMATIC RF182C, SIPLUS NET CP 343-1 Advanced, SIPLUS NET CP 443-1, SIPLUS NET CP 443-1 Advanced, SIPLUS NET SCALANCE X308-2. La pila TCP de Profinet basada en VxWorks puede verse obligada a realizar llamadas muy costosas por cada paquete entrante, lo que puede provocar una denegación de servicio • https://cert-portal.siemens.com/productcert/pdf/ssa-102233.pdf • CWE-400: Uncontrolled Resource Consumption •

CVSS: 7.8EPSS: 0%CPEs: 109EXPL: 0

Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that include a vulnerable version of the stack. The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the device. Las versiones de la pila Profinet-IO (PNIO) anteriores a la V06.00 no limitan adecuadamente la asignación de recursos internos cuando se envían múltiples solicitudes legítimas de paquetes de diagnóstico a la interfaz DCE-RPC. Esto podría conducir a una condición de denegación de servicio debido a la falta de memoria para los dispositivos que incluyen una versión vulnerable de la pila. • https://cert-portal.siemens.com/productcert/html/ssa-780073.html https://cert-portal.siemens.com/productcert/pdf/ssa-780073.pdf • CWE-400: Uncontrolled Resource Consumption •

CVSS: 6.5EPSS: 0%CPEs: 26EXPL: 0

A vulnerability has been identified in SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC CP 343-1 (incl. SIPLUS variants) (All versions), SIMATIC CP 343-1 Advanced (incl. SIPLUS variants) (All versions), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 Advanced (All versions < V3.3), SIMATIC ET 200pro IM154-8 PN/DP CPU (All versions < V3.2.16), SIMATIC ET 200pro IM154-8F PN/DP CPU (All versions < V3.2.16), SIMATIC ET 200pro IM154-8FX PN/DP CPU (All versions < V3.2.16), SIMATIC ET 200S IM151-8 PN/DP CPU (All versions < V3.2.16), SIMATIC ET 200S IM151-8F PN/DP CPU (All versions < V3.2.16), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V1.7.0), SIMATIC S7-1500 Software Controller (All versions < V1.7.0), SIMATIC S7-300 CPU 314C-2 PN/DP (All versions < V3.3.16), SIMATIC S7-300 CPU 315-2 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 315F-2 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 315T-3 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 317-2 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 317F-2 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 317T-3 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 317TF-3 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 319-3 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 319F-3 PN/DP (All versions < V3.2.16), SIMATIC S7-400 CPU 412-2 PN V7 (All versions < V7.0.3), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.9), SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.7), SIMATIC S7-410 CPU family (incl. • https://cert-portal.siemens.com/productcert/pdf/ssa-592007.pdf • CWE-20: Improper Input Validation •

CVSS: 7.1EPSS: 0%CPEs: 181EXPL: 0

Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. This vulnerability affects only SIMATIC HMI Multi Panels and HMI Mobile Panels, and S7-300/S7-400 devices. Los paquetes PROFINET DCP especialmente diseñados que se envían en un segmento Ethernet local (capa 2) a un producto afectado podrían causar una condición de denegación de servicio de ese producto. • http://www.securityfocus.com/bid/98369 http://www.securitytracker.com/id/1038463 https://cert-portal.siemens.com/productcert/html/ssa-293562.html https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf • CWE-400: Uncontrolled Resource Consumption •

CVSS: 7.1EPSS: 0%CPEs: 209EXPL: 0

Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected. Los paquetes de difusión PROFINET DCP especialmente elaborados podrían causar una condición de denegación de servicio de los productos afectados en un segmento Ethernet local (capa 2). Se requiere la interacción humana para recuperar los sistemas. • http://www.securityfocus.com/bid/98369 http://www.securitytracker.com/id/1038463 https://cert-portal.siemens.com/productcert/html/ssa-284673.html https://cert-portal.siemens.com/productcert/html/ssa-293562.html https://cert-portal.siemens.com/productcert/html/ssa-546832.html https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf https://ics-cert.us- • CWE-400: Uncontrolled Resource Consumption •