Page 2 of 11 results (0.008 seconds)

CVSS: 7.5EPSS: 0%CPEs: 96EXPL: 0

A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations. • https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf • CWE-401: Missing Release of Memory after Effective Lifetime •

CVSS: 7.5EPSS: 0%CPEs: 96EXPL: 0

A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1200 CPU family (incl. • https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf • CWE-672: Operation on a Resource after Expiration or Release •

CVSS: 7.5EPSS: 0%CPEs: 96EXPL: 0

A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations. • https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf • CWE-672: Operation on a Resource after Expiration or Release •

CVSS: 6.5EPSS: 0%CPEs: 72EXPL: 0

Domain-bypass transient execution vulnerability in some Intel Atom(R) Processors may allow an authenticated user to potentially enable information disclosure via local access. Una vulnerabilidad en la ejecución transitoria de omisión de dominios en algunos procesadores Intel Atom® puede permitir a un usuario autenticado permitir potencialmente una divulgación de información por medio de un acceso local A potential domain bypass transient execution vulnerability was discovered on some Intel Atom® processors that uses a microarchitectural incidental channel. Currently this channel can reveal supervisor data in the L1 cache and the contents of recent stores. As a consequence, this issue may allow an authenticated user to potentially enable information disclosure via local access. • https://cert-portal.siemens.com/productcert/pdf/ssa-309571.pdf https://lists.debian.org/debian-lts-announce/2021/07/msg00022.html https://www.debian.org/security/2021/dsa-4934 https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00465.html https://access.redhat.com/security/cve/CVE-2020-24513 https://bugzilla.redhat.com/show_bug.cgi?id=1962666 • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •

CVSS: 6.8EPSS: 0%CPEs: 49EXPL: 0

Insufficient control flow management in subsystem for Intel(R) CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25 , Intel(R) TXE versions before 3.1.80 and 4.0.30 may allow an unauthenticated user to potentially enable escalation of privilege via physical access. Una administración de flujo de control insuficiente en el subsistema para Intel® CSME versiones anteriores a 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 y 14.5.25, Intel® TXE versiones anteriores a 3.1.80 y 4.0.30, pueden habilitar a un usuario no autenticado para permitir potencialmente una escalada de privilegios por medio de un acceso físico • https://cert-portal.siemens.com/productcert/pdf/ssa-678983.pdf https://security.netapp.com/advisory/ntap-20201113-0002 https://security.netapp.com/advisory/ntap-20201113-0005 https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00391 •