Page 2 of 6 results (0.001 seconds)

CVSS: 8.8EPSS: 0%CPEs: 23EXPL: 0

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Panels 4" - 22", SIMATIC HMI Comfort Outdoor Panels 7" 15" (todas las versiones anteriores a V14 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 y KTP900F (todas las versiones anteriores a V14), SIMATIC WinCC Runtime Advanced (todas las versiones anteriores a V14), SIMATIC WinCC Runtime Professional (todas las versiones anteriores a V14), SIMATIC WinCC (TIA Portal) (todas las versiones anteriores a V14) y SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (todas las versiones). • http://www.securityfocus.com/bid/105931 https://cert-portal.siemens.com/productcert/pdf/ssa-944083.pdf • CWE-20: Improper Input Validation CWE-113: Improper Neutralization of CRLF Sequences in HTTP Headers ('HTTP Request/Response Splitting') •