Page 2 of 21 results (0.001 seconds)

CVSS: 7.2EPSS: 0%CPEs: 39EXPL: 0

16 Jun 2021 — In the kernel in Insyde InsydeH2O 5.x, certain SMM drivers did not correctly validate the CommBuffer and CommBufferSize parameters, allowing callers to corrupt either the firmware or the OS memory. The fixed versions for this issue in the AhciBusDxe, IdeBusDxe, NvmExpressDxe, SdHostDriverDxe, and SdMmcDeviceDxe drivers are 05.16.25, 05.26.25, 05.35.25, 05.43.25, and 05.51.25 (for Kernel 5.1 through 5.5). En el kernel de Insyde InsydeH2O 5.x, algunos controladores SMM no validaban correctamente los parámetro... • https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf • CWE-20: Improper Input Validation •

CVSS: 6.4EPSS: 0%CPEs: 567EXPL: 0

09 Jun 2021 — Race condition in the firmware for some Intel(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access. Una condición de carrera en el firmware de algunos Intel® Processors puede habilitar a un usuario privilegiado para permitir potencialmente una escalada de privilegios por medio de un acceso local • https://cert-portal.siemens.com/productcert/pdf/ssa-309571.pdf • CWE-362: Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition') •

CVSS: 6.7EPSS: 0%CPEs: 568EXPL: 0

09 Jun 2021 — Improper initialization in the firmware for some Intel(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access. Una inicialización inapropiada en el firmware de algunos Intel® Processors puede habilitar a un usuario privilegiado para permitir potencialmente una escalada de privilegios por medio de un acceso local • https://cert-portal.siemens.com/productcert/pdf/ssa-309571.pdf • CWE-665: Improper Initialization •

CVSS: 4.4EPSS: 0%CPEs: 333EXPL: 0

09 Jun 2021 — Out of bound read in a subsystem in the Intel(R) CSME versions before 12.0.81, 13.0.47, 13.30.17, 14.1.53 and 14.5.32 may allow a privileged user to potentially enable information disclosure via local access. Una lectura fuera de límites de un subsistema en Intel® CSME versiones anteriores a 12.0.81, 13.0.47, 13.30.17, 14.1.53 y 14.5.32 puede permitir a un usuario privilegiado habilitar potencialmente una divulgación de información por medio de un acceso local • https://cert-portal.siemens.com/productcert/pdf/ssa-309571.pdf • CWE-125: Out-of-bounds Read •

CVSS: 6.7EPSS: 0%CPEs: 576EXPL: 0

09 Jun 2021 — Improper buffer restrictions in a subsystem in the Intel(R) CSME versions before 11.8.86, 11.12.86, 11.22.86, 12.0.81, 13.0.47, 13.30.17, 14.1.53, 14.5.32 and 15.0.22 may allow a privileged user to potentially enable escalation of privilege via local access. Unas restricciones de búfer inapropiadas en un subsistema en Intel® CSME versiones anteriores a 11.8.86, 11.12.86, 11.22.86, 12.0.81, 13.0.47, 13.30.17, 14.1.53, 14.5.32 y 15.0.22 pueden permitir a un usuario privilegiado habilitar potencialmente una es... • https://cert-portal.siemens.com/productcert/pdf/ssa-309571.pdf • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •

CVSS: 4.4EPSS: 0%CPEs: 618EXPL: 0

09 Jun 2021 — Improper initialization in a subsystem in the Intel(R) CSME versions before 11.8.86, 11.12.86, 11.22.86, 12.0.81, 13.0.47, 13.30.17, 14.1.53, 14.5.32, 13.50.11 and 15.0.22 may allow a privileged user to potentially enable information disclosure via local access. Una inicialización inapropiada en un subsistema en Intel® CSME versiones anteriores a 11.8.86, 11.12.86, 11.22.86, 12.0.81, 13.0.47, 13.30.17, 14.1.53, 14.5.32, 13.50.11 y 15.0.22 puede habilitar a un usuario privilegiado para permitir potencialment... • https://cert-portal.siemens.com/productcert/pdf/ssa-309571.pdf • CWE-665: Improper Initialization •

CVSS: 6.4EPSS: 0%CPEs: 25EXPL: 0

09 Jun 2021 — Race condition in a subsystem in the Intel(R) LMS versions before 2039.1.0.0 may allow a privileged user to potentially enable escalation of privilege via local access. Una condición de carrera en un subsistema en las versiones anteriores a 2039.1.0.0 de Intel® LMS puede habilitar a un usuario privilegiado para permitir potencialmente una escalada de privilegios por medio de un acceso local • https://cert-portal.siemens.com/productcert/pdf/ssa-309571.pdf • CWE-362: Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition') •

CVSS: 6.8EPSS: 0%CPEs: 49EXPL: 0

12 Nov 2020 — Insufficient control flow management in subsystem for Intel(R) CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25 , Intel(R) TXE versions before 3.1.80 and 4.0.30 may allow an unauthenticated user to potentially enable escalation of privilege via physical access. Una administración de flujo de control insuficiente en el subsistema para Intel® CSME versiones anteriores a 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 y 14.5.25, Intel® TXE versi... • https://cert-portal.siemens.com/productcert/pdf/ssa-678983.pdf •

CVSS: 7.8EPSS: 0%CPEs: 271EXPL: 0

12 Nov 2020 — Improper input validation in BIOS firmware for some Intel(R) Processors may allow an authenticated user to potentially enable escalation of privilege via local access. Una comprobación inapropiada de la entrada en el firmware del BIOS para algunos Intel® Processors puede habilitar a un usuario autenticado para permitir potencialmente una escalada de privilegios por medio de un acceso local • https://cert-portal.siemens.com/productcert/pdf/ssa-678983.pdf • CWE-20: Improper Input Validation •

CVSS: 5.5EPSS: 0%CPEs: 49EXPL: 0

11 Nov 2020 — Improper isolation of shared resources in some Intel(R) Processors may allow an authenticated user to potentially enable information disclosure via local access. Un aislamiento inapropiado de los recursos compartidos en algunos Intel® Processors, puede habilitar a un usuario autenticado para permitir potencialmente una divulgación de información por medio de un acceso local A flaw was found in the CPU microarchitecture where a local attacker is able to abuse a timing issue which may allow them to infer inte... • https://cert-portal.siemens.com/productcert/pdf/ssa-678983.pdf • CWE-212: Improper Removal of Sensitive Information Before Storage or Transfer CWE-668: Exposure of Resource to Wrong Sphere •