Page 2 of 12 results (0.002 seconds)

CVSS: 5.4EPSS: 0%CPEs: 1EXPL: 0

A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). There is a stored cross-site scripting vulnerability in the Administration Console of the affected product, that could allow an attacker with high privileges to inject Javascript code into the application that is later executed by another legitimate user. Se ha identificado una vulnerabilidad en SIMATIC PCS neo (todas las versiones &lt; V4.1). Existe una vulnerabilidad de cross-site scripting almacenada en la Consola de Administración del producto afectado, que podría permitir a un atacante con altos privilegios inyectar código Javascript en la aplicación que luego será ejecutado por otro usuario legítimo. • https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVSS: 8.8EPSS: 0%CPEs: 1EXPL: 0

A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). When accessing the Information Server from affected products, the products use an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior. Se ha identificado una vulnerabilidad en SIMATIC PCS neo (todas las versiones &lt; V4.1). Al acceder al servidor de información desde los productos afectados, los productos utilizan una política CORS demasiado permisiva. • https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf • CWE-942: Permissive Cross-domain Policy with Untrusted Domains •

CVSS: 8.0EPSS: 0%CPEs: 1EXPL: 0

A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). The PUD Manager of affected products does not properly neutralize user provided inputs. This could allow an authenticated adjacent attacker to execute SQL statements in the underlying database. Se ha identificado una vulnerabilidad en SIMATIC PCS neo (todas las versiones &lt; V4.1). El PUD Manager de los productos afectados no neutraliza adecuadamente las entradas proporcionadas por el usuario. • https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf • CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') •

CVSS: 6.5EPSS: 0%CPEs: 1EXPL: 0

A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). The PUD Manager of affected products does not properly authenticate users in the PUD Manager web service. This could allow an unauthenticated adjacent attacker to generate a privileged token and upload additional documents. Se ha identificado una vulnerabilidad en SIMATIC PCS neo (todas las versiones &lt; V4.1). El PUD Manager de los productos afectados no autentica adecuadamente a los usuarios en el servicio web PUD Manager. • https://cert-portal.siemens.com/productcert/pdf/ssa-456933.pdf • CWE-306: Missing Authentication for Critical Function •

CVSS: 7.8EPSS: 0%CPEs: 7EXPL: 0

A vulnerability has been identified in SIMATIC PCS neo (Administration Console) (All versions < V3.1 SP1), SINETPLAN (All versions), TIA Portal (V15, V15.1, V16 and V17). The affected system cannot properly process specially crafted packets sent to port 8888/tcp. A remote attacker could exploit this vulnerability to cause a Denial-of-Service condition. The affected devices must be restarted manually. Se ha identificado una vulnerabilidad en SIMATIC PCS neo (Consola de Administración) (todas las versiones anteriores a V3.1 SP1), SINETPLAN (Todas las versiones), TIA Portal (versiones V15, V15.1, V16 y V17). • https://cert-portal.siemens.com/productcert/pdf/ssa-711829.pdf • CWE-400: Uncontrolled Resource Consumption •