Page 2 of 11 results (0.003 seconds)

CVSS: 7.5EPSS: 0%CPEs: 96EXPL: 0

A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1200 CPU family (incl. • https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf • CWE-672: Operation on a Resource after Expiration or Release •

CVSS: 7.5EPSS: 0%CPEs: 96EXPL: 0

A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations. • https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf • CWE-672: Operation on a Resource after Expiration or Release •

CVSS: 7.8EPSS: 0%CPEs: 18EXPL: 0

Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to TCP port 102 (aka the ISO-TSAP port). Siemens SIMATIC S7-1200 PLCs v2.x y v3.x ermite a atacantes remotos causar una denegación de servicios (transición de modo defecto e interrupción de control) a través de paquetes TCP manipulados dirigidos al puerto 102 (conocido como puerto ISO-TSAP). • http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf •

CVSS: 7.8EPSS: 0%CPEs: 18EXPL: 0

Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port). Siemens SIMATIC S7-1200 PLCs v2.x y v3.x permite a atacantes remotos causar una denegación de servicio mediante paquetes especialmente creados hacia el puerto UDP 161 (puerto SNMP) • http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf •

CVSS: 4.3EPSS: 0%CPEs: 18EXPL: 0

Cross-site scripting (XSS) vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI. Vulnerabilidad de ejecución de secuencias de comandos en sitios cruzados (XSS) en el servidor web SIMATIC S7-1200 PLCs v2.x hasta v3.0.1 permite a atacantes remotos inyectar secuencias de comandos web o HTML a través de una URI específicamente construida. • http://en.securitylab.ru/lab/PT-2012-50 http://osvdb.org/86130 http://secunia.com/advisories/50816 http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-279823.pdf http://www.us-cert.gov/control_systems/pdf/ICSA-12-283-01.pdf • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •