Page 2 of 17 results (0.002 seconds)

CVSS: 7.5EPSS: 0%CPEs: 184EXPL: 0

Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device. Los dispositivos afectados no procesan correctamente ciertos paquetes especialmente manipulados enviados al puerto 102/tcp, lo que podría permitir a un atacante provocar una denegación de servicio en el dispositivo. • https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf • CWE-20: Improper Input Validation CWE-1287: Improper Validation of Specified Type of Input •

CVSS: 7.5EPSS: 0%CPEs: 192EXPL: 0

Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device. Los dispositivos afectados no procesan correctamente ciertos paquetes especialmente manipulados enviados al puerto 102/tcp, lo que podría permitir a un atacante provocar una denegación de servicio en el dispositivo. • https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf • CWE-1284: Improper Validation of Specified Quantity in Input •

CVSS: 6.5EPSS: 0%CPEs: 223EXPL: 0

The login endpoint /FormLogin in affected web services does not apply proper origin checking. This could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack. El endpoint de inicio de sesión /FormLogin en los servicios web afectados no aplica la verificación de origen adecuada. Esto podría permitir a atacantes remotos autenticados rastrear las actividades de otros usuarios mediante un ataque de Cross-Site Request Forgery (CSRF). • https://cert-portal.siemens.com/productcert/pdf/ssa-478960.pdf • CWE-352: Cross-Site Request Forgery (CSRF) •

CVSS: 9.3EPSS: 0%CPEs: 89EXPL: 0

A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINUMERIK MC (All versions < V6.21), SINUMERIK ONE (All versions < V6.21). Affected products protect the built-in global private key in a way that cannot be considered sufficient any longer. • https://cert-portal.siemens.com/productcert/pdf/ssa-568427.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-568428.pdf • CWE-522: Insufficiently Protected Credentials •

CVSS: 7.5EPSS: 0%CPEs: 96EXPL: 0

A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations. • https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf • CWE-401: Missing Release of Memory after Effective Lifetime •