Page 2 of 14 results (0.003 seconds)

CVSS: 7.5EPSS: 0%CPEs: 184EXPL: 0

Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device. Los dispositivos afectados no procesan correctamente ciertos paquetes especialmente manipulados enviados al puerto 102/tcp, lo que podría permitir a un atacante provocar una denegación de servicio en el dispositivo. • https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf • CWE-20: Improper Input Validation CWE-1287: Improper Validation of Specified Type of Input •

CVSS: 7.5EPSS: 0%CPEs: 192EXPL: 0

Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device. Los dispositivos afectados no procesan correctamente ciertos paquetes especialmente manipulados enviados al puerto 102/tcp, lo que podría permitir a un atacante provocar una denegación de servicio en el dispositivo. • https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf • CWE-1284: Improper Validation of Specified Quantity in Input •

CVSS: 6.5EPSS: 0%CPEs: 223EXPL: 0

The login endpoint /FormLogin in affected web services does not apply proper origin checking. This could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack. El endpoint de inicio de sesión /FormLogin en los servicios web afectados no aplica la verificación de origen adecuada. Esto podría permitir a atacantes remotos autenticados rastrear las actividades de otros usuarios mediante un ataque de Cross-Site Request Forgery (CSRF). • https://cert-portal.siemens.com/productcert/pdf/ssa-478960.pdf • CWE-352: Cross-Site Request Forgery (CSRF) •

CVSS: 9.3EPSS: 0%CPEs: 89EXPL: 0

A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINUMERIK MC (All versions < V6.21), SINUMERIK ONE (All versions < V6.21). Affected products protect the built-in global private key in a way that cannot be considered sufficient any longer. • https://cert-portal.siemens.com/productcert/pdf/ssa-568427.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-568428.pdf • CWE-522: Insufficiently Protected Credentials •

CVSS: 7.8EPSS: 0%CPEs: 78EXPL: 0

A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) V15 (All versions), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 5), SIMATIC STEP 7 (TIA Portal) V17 (All versions < V17 Update 2). An attacker could achieve privilege escalation on the web server of certain devices due to improper access control vulnerability in the engineering system software. The attacker needs to have direct access to the impacted web server. Se ha identificado una vulnerabilidad en SIMATIC STEP 7 (TIA Portal) versión V15 (Todas las versiones), SIMATIC STEP 7 (TIA Portal) versión V16 (todas las versiones anteriores a versión V16 Update 5), SIMATIC STEP 7 (TIA Portal) versión V17 (todas las versiones anteriores a versión V17 Update 2). Un atacante podría lograr una escalada de privilegios en el servidor web de determinados dispositivos debido a una vulnerabilidad de control de acceso inapropiada en el software del sistema de ingeniería. • https://cert-portal.siemens.com/productcert/pdf/ssa-350757.pdf • CWE-284: Improper Access Control •