CVE-2021-44693
https://notcve.org/view.php?id=CVE-2021-44693
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device. Los dispositivos afectados no procesan correctamente ciertos paquetes especialmente manipulados enviados al puerto 102/tcp, lo que podría permitir a un atacante provocar una denegación de servicio en el dispositivo. • https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf • CWE-1284: Improper Validation of Specified Quantity in Input •
CVE-2022-38465
https://notcve.org/view.php?id=CVE-2022-38465
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINUMERIK MC (All versions < V6.21), SINUMERIK ONE (All versions < V6.21). Affected products protect the built-in global private key in a way that cannot be considered sufficient any longer. • https://cert-portal.siemens.com/productcert/pdf/ssa-568427.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-568428.pdf • CWE-522: Insufficiently Protected Credentials •
CVE-2020-28400
https://notcve.org/view.php?id=CVE-2020-28400
Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device. Los dispositivos afectados contienen una vulnerabilidad que permite a un atacante no autentificado desencadenar una condición de denegación de servicio. La vulnerabilidad puede activarse si se envía una gran cantidad de paquetes de restablecimiento de DCP al dispositivo • https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03 https://cert-portal.siemens.com/productcert/html/ssa-599968.html • CWE-770: Allocation of Resources Without Limits or Throttling •
CVE-2021-3449 – NULL pointer deref in signature_algorithms processing
https://notcve.org/view.php?id=CVE-2021-3449
An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. • http://www.openwall.com/lists/oss-security/2021/03/27/1 http://www.openwall.com/lists/oss-security/2021/03/27/2 http://www.openwall.com/lists/oss-security/2021/03/28/3 http://www.openwall.com/lists/oss-security/2021/03/28/4 https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148 https://kb.pulse • CWE-476: NULL Pointer Dereference •
CVE-2020-7584
https://notcve.org/view.php?id=CVE-2020-7584
A vulnerability has been identified in SIMATIC S7-200 SMART CPU family (All versions >= V2.2 < V2.5.1). Affected devices do not properly handle large numbers of new incomming connections and could crash under certain circumstances. An attacker may leverage this to cause a Denial-of-Service situation. Se ha identificado una vulnerabilidad en la familia de CPU SIMATIC S7-200 SMART (Todas las versiones posteriores e incluyendo a V2.2 anteriores a V2.5.1). Los dispositivos afectados no manejan apropiadamente un gran número de nuevas conexiones entrantes y podrían bloquearse bajo determinadas circunstancias. • https://cert-portal.siemens.com/productcert/pdf/ssa-589181.pdf • CWE-400: Uncontrolled Resource Consumption •