Page 2 of 16 results (0.006 seconds)

CVSS: 7.2EPSS: 0%CPEs: 44EXPL: 0

A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges. Se ha identificado una vulnerabilidad en SIMATIC Automation Tool (Todas las versiones anteriores a la versión V4 SP2), SIMATIC NET PC Software V14 (Todas las versiones anteriores a la versión V14 SP1 Update 14), SIMATIC NET PC Software V15 (Todas las versiones), SIMATIC NET PC Software V16 (Todas las versiones anteriores a la versión V16 Upd3), SIMATIC PCS neo (Todas las versiones anteriores a la versión V3.0 SP1), SIMATIC ProSave (Todas las versiones anteriores a la versión V17), SIMATIC S7-1500 Software Controller (Todas las versiones anteriores a la versión V21. 8), SIMATIC STEP 7 (Todas las versiones anteriores a la versión V5.6 SP2 HF3), SIMATIC STEP 7 (TIA Portal) V13 (Todas las versiones anteriores a la versión V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (Todas las versiones anteriores a la versión V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (Todas las versiones anteriores a la versión V15. 1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (Todas las versiones anteriores a la versión V16 Update 2), SIMATIC WinCC OA V3.16 (Todas las versiones anteriores a la versión V3.16 P018), SIMATIC WinCC OA V3. 17 (Todas las versiones anteriores a la versión V3.17 P003), SIMATIC WinCC Runtime Advanced (Todas las versiones anteriores a la versión V16 Update 2), SIMATIC WinCC Runtime Professional V13 (Todas las versiones anteriores a la versión V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (Todas las versiones anteriores a la versión V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (Todas las versiones anteriores a la versión V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (Todas las versiones anteriores a la versión V16 Update 2), SIMATIC WinCC V7. 4 (Todas las versiones anteriores a la versión V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (Todas las versiones anteriores a la versión V7.5 SP1 Update 3), SINAMICS STARTER (Todas las versiones anteriores a la versión V5.4 HF2), SINAMICS Startdrive (Todas las versiones anteriores a la versión V16 Update 3), SINEC NMS (Todas las versiones anteriores a la versión V1. 0 SP2), SINEMA Server (Todas las versiones anteriores a la versión V14 SP3), SINUMERIK ONE virtual (Todas las versiones anteriores a la versión V6.14), SINUMERIK Operate (Todas las versiones anteriores a la versión V6.14). Un componente dentro de la aplicación afectada llama regularmente a un binario de ayuda con privilegios de SISTEMA mientras la ruta de llamada no está citada • https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04 • CWE-428: Unquoted Search Path or Element •

CVSS: 5.9EPSS: 0%CPEs: 36EXPL: 0

A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC STEP 7 (TIA Portal) (All versions < V16), SIMATIC WinCC (TIA Portal) (All versions < V16), SIMATIC WinCC OA (All versions < V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions < V16), SIMATIC WinCC Runtime Professional (All versions < V16), TIM 1531 IRC (incl. • https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf https://www.us-cert.gov/ics/advisories/icsa-19-344-04 • CWE-327: Use of a Broken or Risky Cryptographic Algorithm •

CVSS: 6.9EPSS: 0%CPEs: 27EXPL: 0

A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 V5.X (All versions < V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions < V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions < V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions < V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions < V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions < V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions < V7.4 SP1), SIMIT V9.0 (All versions < V9.0 SP1), SINEMA Remote Connect Client (All versions < V1.0 SP3), SINEMA Server (All versions < V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions < V4.3 HF1), TeleControl Server Basic (All versions < V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path ("C:\Program Files\*" or the localized equivalent). Se ha identificado una vulnerabilidad en Primary Setup Tool (PST) (todas las versiones anteriores a V4.2 HF1), SIMATIC IT Production Suite (todas las versiones anteriores a V7.0 SP1 HFX 2), SIMATIC NET PC-Software (Todas las versiones anteriores a V14), SIMATIC PCS 7 versión V7.1 (Todas las versiones), SIMATIC PCS 7 versión V8.0 (Todas las versiones), SIMATIC PCS 7 versión V8.1 (Todas las versiones),SIMATIC PCS 7 versión V8.2 (Todas las versiones anteriores a V8.2 SP1), SIMATIC STEP 7 (TIA Portal) versión V13 (Todas las versiones anteriores a V13 SP2), SIMATIC STEP 7 versiones V5.X (Todas las versiones anteriores a V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (Todas las versiones anteriores a V14), SIMATIC WinCC (TIA Portal) Professional versión V13 (Todas las versiones anteriores a V13 SP2), SIMATIC WinCC (TIA Portal) Professional versión V14 (Todas las versiones anteriores a V14 SP1), SIMATIC WinCC Runtime Professional versión V13 (Todas las versiones anteriores a V13 SP2), SIMATIC WinCC Runtime Professional versión V14 (Todas las versiones anteriores a V14 SP1), SIMATIC WinCC versión V7.0 SP2 y anteriores (Todas las versiones anteriores a V7.0 SP2 Upd 12), SIMATIC WinCC versión V7.0 SP3 (Todas las versiones anteriores a V7.0 SP3 Upd 8), SIMATIC WinCC versión V7.2 (Todas las versiones anteriores a V7.2 Upd 14), SIMATIC WinCC versión V7.3 (Todas las versiones anteriores a V7.3 Upd 11), SIMATIC WinCC versión V7.4 (Todas las versiones anteriores a V7.4 SP1), SIMIT versión V9.0 (Todas las versiones anteriores a V9.0 SP1), SINEMA Remote Connect Client (Todas las versiones anteriores a V1.0 SP3), SINEMA Server (Todas las versiones anteriores a V13 SP2), SOFTNET Security Client versión V5.0 (Todas las versiones), Security Configuration Tool (SCT) (Todas las versiones anteriores a V4.3 HF1), TeleControl Server Basic (Todas las versiones anteriores a V3.0 SP2), WinAC RTX 2010 SP2 (Todas las versiones), WinAC RTX F 2010 SP2 (Todas las versiones). Las rutas (path) de servicio sin comillas podrían permitir que los usuarios locales del sistema operativo Microsoft Windows aumenten sus privilegios si los productos afectados no están instalados en su ruta (path) de acceso predeterminada ("C:\Program Files\*" o el equivalente localizado). • http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html http://www.securityfocus.com/bid/94158 https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02 • CWE-254: 7PK - Security Features CWE-284: Improper Access Control •

CVSS: 4.7EPSS: 0%CPEs: 1EXPL: 0

Siemens SIMATIC STEP 7 (TIA Portal) before 14 improperly stores pre-shared key data in TIA project files, which makes it easier for local users to obtain sensitive information by leveraging access to a file and conducting a brute-force attack. Siemens SIMATIC STEP 7 (TIA Portal) en versiones anteriores a 14 almacena indebidamente los datos clave pre-compartidos en archivos de proyecto TIA, lo que hace más que sea más fácil para usuarios locales obtener información sensible aprovechando el acceso a un archivo y llevando a cabo un ataque de fuerza bruta. • http://www.securityfocus.com/bid/93551 http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-869766.pdf https://ics-cert.us-cert.gov/advisories/ICSA-16-287-03 • CWE-254: 7PK - Security Features •

CVSS: 2.5EPSS: 0%CPEs: 1EXPL: 0

Siemens SIMATIC STEP 7 (TIA Portal) before 14 uses an improper format for managing TIA project files during version updates, which makes it easier for local users to obtain sensitive configuration information via unspecified vectors. Siemens SIMATIC STEP 7 (TIA Portal) en versiones anteriores a 14 utiliza un formato indebido para la gestión de archivos de proyectos TIA durante las actualizaciones de versión, lo que hace que sea más fácil para usuarios locales obtener información de configuración sensible a través de vectores no especificados. • http://www.securityfocus.com/bid/93551 http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-869766.pdf https://ics-cert.us-cert.gov/advisories/ICSA-16-287-03 • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •