Page 2 of 109 results (0.003 seconds)

CVSS: 8.2EPSS: 0%CPEs: 13EXPL: 0

A vulnerability has been identified in S7-PCT (All versions), Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software V16 (All versions), SIMATIC NET PC Software V17 (All versions), SIMATIC NET PC Software V18 (All versions < V18 SP1), SIMATIC PCS 7 V9.1 (All versions), SIMATIC PDM V9.2 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC STEP 7 V5 (All versions), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions < V3.18 P025), SIMATIC WinCC OA V3.19 (All versions < V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 6), SIMATIC WinCC Runtime Professional V17 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC Unified PC Runtime (All versions), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5), SINAMICS Startdrive (All versions < V19 SP1), SINUMERIK ONE virtual (All versions < V6.23), SINUMERIK PLC Programming Tool (All versions), TIA Portal Cloud Connector (All versions < V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 4), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 2). The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel. Se ha identificado una vulnerabilidad en: S7-PCT (todas las versiones), Security Configuration Tool (SCT) (todas las versiones), SIMATIC Automation Tool (todas las versiones), SIMATIC BATCH V9.1 (todas las versiones), SIMATIC NET PC Software (todas las versiones), SIMATIC PCS 7 V9.1 (todas las versiones), SIMATIC PDM V9.2 (todas las versiones), SIMATIC Route Control V9.1 (todas las versiones), SIMATIC STEP 7 V5 (todas las versiones), SIMATIC WinCC OA V3.17 ( Todas las versiones), SIMATIC WinCC OA V3.18 (todas las versiones &lt; V3.18 P025), SIMATIC WinCC OA V3.19 (todas las versiones &lt; V3.19 P010), SIMATIC WinCC Runtime Advanced (todas las versiones), SIMATIC WinCC Runtime Professional V16 (Todas las versiones), SIMATIC WinCC Runtime Professional V17 (todas las versiones), SIMATIC WinCC Runtime Professional V18 (todas las versiones), SIMATIC WinCC Runtime Professional V19 (todas las versiones), SIMATIC WinCC Unified PC Runtime (todas las versiones), SIMATIC WinCC V7.4 (Todas las versiones), SIMATIC WinCC V7.5 (Todas las versiones), SIMATIC WinCC V8.0 (Todas las versiones), SINAMICS Startdrive (Todas las versiones &lt; V19 SP1), SINUMERIK ONE virtual (Todas las versiones &lt; V6.23), Programación de PLC SINUMERIK Herramienta (todas las versiones), TIA Portal Cloud Connector (todas las versiones &lt; V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V16 (todas las versiones), Totally Portal de automatización integrado (TIA Portal) V17 (todas las versiones), Portal de automatización totalmente integrado (Portal TIA) V18 (todas las versiones), Portal de automatización totalmente integrado (TIA Portal) V19 (todas las versiones A vulnerability has been identified in S7-PCT (All versions), Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions < V5.0 SP2), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 Upd5), SIMATIC NET PC Software V16 (All versions < V16 Update 8), SIMATIC NET PC Software V17 (All versions), SIMATIC NET PC Software V18 (All versions < V18 SP1), SIMATIC NET PC Software V19 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PDM V9.2 (All versions < V9.2 SP2 Upd3), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 Upd3), SIMATIC STEP 7 V5 (All versions), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions < V3.18 P025), SIMATIC WinCC OA V3.19 (All versions < V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 6), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC Unified PC Runtime V18 (All versions), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5), SINAMICS Startdrive (All versions < V19 SP1), SINEC NMS (All versions < V3.0), SINUMERIK ONE virtual (All versions < V6.23), SINUMERIK PLC Programming Tool (All versions), TIA Portal Cloud Connector (All versions < V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 4), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 2). The affected applications contain an out of bounds read vulnerability. • https://cert-portal.siemens.com/productcert/html/ssa-962515.html https://cert-portal.siemens.com/productcert/html/ssa-784301.html • CWE-125: Out-of-bounds Read •

CVSS: 6.9EPSS: 0%CPEs: 1EXPL: 0

A vulnerability has been identified in SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC04), SIMATIC WinCC Runtime Professional V17 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 1), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 16), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products do not properly validate the input provided in the login dialog box. An attacker could leverage this vulnerability to cause a persistent denial of service condition. Se ha identificado una vulnerabilidad en SIMATIC PCS 7 V9.1 (todas las versiones &lt; V9.1 SP2 UC04), SIMATIC WinCC Runtime Professional V17 (todas las versiones), SIMATIC WinCC Runtime Professional V18 (todas las versiones &lt; V18 Update 4), SIMATIC WinCC Runtime Professional V19 (todas las versiones &lt; V19 Update 1), SIMATIC WinCC V7.5 (todas las versiones &lt; V7.5 SP2 Update 16), SIMATIC WinCC V8.0 (todas las versiones &lt; V8.0 Update 5). Los productos afectados no validan correctamente la entrada proporcionada en el cuadro de diálogo de inicio de sesión. • https://cert-portal.siemens.com/productcert/html/ssa-730482.html • CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') •

CVSS: 7.1EPSS: 0%CPEs: 4EXPL: 0

A vulnerability has been identified in OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain malformed RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server. Se ha identificado una vulnerabilidad en: OpenPCS 7 V9.1 (todas las versiones), SIMATIC BATCH V9.1 (todas las versiones), SIMATIC PCS 7 V9.1 (todas las versiones), SIMATIC Route Control V9.1 (todas las versiones), SIMATIC WinCC Runtime Professional V18 (todas las versiones), SIMATIC WinCC Runtime Professional V19 (todas las versiones), SIMATIC WinCC V7.4 (todas las versiones), SIMATIC WinCC V7.5 (todas las versiones &lt; V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (Todas las versiones A vulnerability has been identified in OpenPCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain malformed RPC messages. • https://cert-portal.siemens.com/productcert/html/ssa-753746.html • CWE-476: NULL Pointer Dereference •

CVSS: 7.1EPSS: 0%CPEs: 4EXPL: 0

A vulnerability has been identified in OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain unorganized RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server. Se ha identificado una vulnerabilidad en: OpenPCS 7 V9.1 (todas las versiones), SIMATIC BATCH V9.1 (todas las versiones), SIMATIC PCS 7 V9.1 (todas las versiones), SIMATIC Route Control V9.1 (todas las versiones), SIMATIC WinCC Runtime Professional V18 (todas las versiones), SIMATIC WinCC Runtime Professional V19 (todas las versiones), SIMATIC WinCC V7.4 (todas las versiones), SIMATIC WinCC V7.5 (todas las versiones &lt; V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (Todas las versiones A vulnerability has been identified in OpenPCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain unorganized RPC messages. • https://cert-portal.siemens.com/productcert/html/ssa-753746.html • CWE-476: NULL Pointer Dereference •

CVSS: 8.8EPSS: 0%CPEs: 7EXPL: 0

A vulnerability has been identified in SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC WinCC (All versions < V8.0), SINAUT Software ST7sc (All versions). Before SIMATIC WinCC V8, legacy OPC services (OPC DA (Data Access), OPC HDA (Historical Data Access), and OPC AE (Alarms & Events)) were used per default. These services were designed on top of the Windows ActiveX and DCOM mechanisms and do not implement state-of-the-art security mechanisms for authentication and encryption of contents. • https://cert-portal.siemens.com/productcert/pdf/ssa-508677.pdf • CWE-477: Use of Obsolete Function •