Page 2 of 10 results (0.016 seconds)

CVSS: 7.5EPSS: 0%CPEs: 44EXPL: 0

A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions < V8.2 Upd12), SIMATIC BATCH V9.0 (All versions < V9.0 SP1 Upd5), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC (TIA Portal) V15.1 (All versions < V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (All versions < V16 Update 1), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 1). Through specially crafted messages, when encrypted communication is enabled, an attacker with network access could use the vulnerability to compromise the availability of the system by causing a Denial-of-Service condition. Successful exploitation requires no system privileges and no user interaction. Se ha identificado una vulnerabilidad en OpenPCS 7 V8.1 (Todas las versiones), OpenPCS 7 V8.2 (Todas las versiones), OpenPCS 7 V9.0 (Todas las versiones anteriores a V9.0 Upd3), SIMATIC BATCH V8.1 (Todas las versiones), SIMATIC BATCH V8.2 (Todas las versiones), SIMATIC BATCH V9.0 (Todas las versiones anteriores a V9. 0 SP1 Upd5), SIMATIC NET PC Software V14 (Todas las versiones anteriores a V14 SP1 Update 14), SIMATIC NET PC Software V15 (Todas las versiones), SIMATIC NET PC Software V16 (Todas las versiones anteriores a V16 Update 1), SIMATIC PCS 7 V8.1 (Todas las versiones), SIMATIC PCS 7 V8.2 (Todas las versiones), SIMATIC PCS 7 V9.0 (Todas las versiones anteriores a V9. 0 SP3), SIMATIC Route Control V8.1 (Todas las versiones), SIMATIC Route Control V8.2 (Todas las versiones), SIMATIC Route Control V9.0 (Todas las versiones anteriores a V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (Todas las versiones anteriores a V13 SP2), SIMATIC WinCC (TIA Portal) V14 (Todas las versiones anteriores a V14 SP1 Update 10), SIMATIC WinCC (TIA Portal) V15. 1 (Todas las versiones anteriores a V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (Todas las versiones anteriores a V16 Update 1), SIMATIC WinCC V7.3 (Todas las versiones), SIMATIC WinCC V7.4 (Todas las versiones anteriores a V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (Todas las versiones anteriores a V7.5 SP1 Update 1). A través de mensajes especialmente diseñados, cuando la comunicación cifrada está habilitada, un atacante con acceso a la red podría utilizar la vulnerabilidad para comprometer la disponibilidad del sistema causando una condición de denegación de servicio. La explotación exitosa no requiere privilegios del sistema ni interacción del usuario • https://cert-portal.siemens.com/productcert/pdf/ssa-270778.pdf • CWE-131: Incorrect Calculation of Buffer Size •

CVSS: 5.9EPSS: 0%CPEs: 36EXPL: 0

A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC STEP 7 (TIA Portal) (All versions < V16), SIMATIC WinCC (TIA Portal) (All versions < V16), SIMATIC WinCC OA (All versions < V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions < V16), SIMATIC WinCC Runtime Professional (All versions < V16), TIM 1531 IRC (incl. • https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf https://www.us-cert.gov/ics/advisories/icsa-19-344-04 • CWE-327: Use of a Broken or Risky Cryptographic Algorithm •

CVSS: 7.2EPSS: 0%CPEs: 32EXPL: 0

A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd 11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC Professional (TIA Portal V13) (All versions), SIMATIC WinCC Professional (TIA Portal V14) (All versions < V14 SP1 Upd 9), SIMATIC WinCC Professional (TIA Portal V15) (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). The SIMATIC WinCC DataMonitor web application of the affected products allows to upload arbitrary ASPX code. The security vulnerability could be exploited by an authenticated attacker with network access to the WinCC DataMonitor application. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. • https://cert-portal.siemens.com/productcert/pdf/ssa-121293.pdf • CWE-434: Unrestricted Upload of File with Dangerous Type •

CVSS: 7.5EPSS: 0%CPEs: 48EXPL: 0

A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions < V8.1 Upd5), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd1), SIMATIC BATCH V7.1 and earlier (All versions), SIMATIC BATCH V8.0 (All versions < V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (All versions < V8.1 SP1 Upd16), SIMATIC BATCH V8.2 (All versions < V8.2 Upd10), SIMATIC BATCH V9.0 (All versions < V9.0 SP1), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions < 15 SP1), SIMATIC PCS 7 V7.1 and earlier (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP1), SIMATIC Route Control V7.1 and earlier (All versions), SIMATIC Route Control V8.0 (All versions), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Upd2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Upd5), SIMATIC WinCC V7.2 and earlier (All versions < WinCC 7.2 Upd 15), SIMATIC WinCC V7.3 (All versions < WinCC 7.3 Upd 16), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 4), SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). Specially crafted messages sent to the RPC service of the affected products could cause a Denial-of-Service condition on the remote and local communication functionality of the affected products. A reboot of the system is required to recover the remote and local communication functionality. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. • http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html https://cert-portal.siemens.com/productcert/pdf/ssa-348629.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf • CWE-20: Improper Input Validation •

CVSS: 4.9EPSS: 0%CPEs: 6EXPL: 0

A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the "administrators" group to crash services by sending specially crafted messages to the DCOM interface. Se detectó una vulnerabilidad en SIMATIC WinCC (versión V7.3 anterior a Upd 11 y versión V7.4 anterior a SP1), SIMATIC WinCC Runtime Professional (versión V13 anterior a SP2 y versión V14 anterior a SP1), SIMATIC WinCC (TIA Portal) Professional (versión V13 anterior a SP2 y versión V14 anterior a SP1) de Siemens, eso podría permitir a un atacante remoto autenticado, quien es miembro del grupo de los "administrators" bloquear los servicios enviando mensajes especialmente diseñados a la interfaz DCOM. • http://www.securityfocus.com/bid/98368 https://cert-portal.siemens.com/productcert/pdf/ssa-523365.pdf https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf • CWE-20: Improper Input Validation CWE-787: Out-of-bounds Write •