Page 2 of 8 results (0.014 seconds)

CVSS: 7.5EPSS: 0%CPEs: 23EXPL: 0

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). A directory traversal vulnerability could allow to download arbitrary files from the device. The security vulnerability could be exploited by an attacker with network access to the integrated web server. No user interaction and no authentication is required to exploit the vulnerability. The vulnerability impacts the confidentiality of the device. • http://www.securityfocus.com/bid/105922 https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •

CVSS: 8.8EPSS: 0%CPEs: 23EXPL: 0

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Panels 4" - 22", SIMATIC HMI Comfort Outdoor Panels 7" 15" (todas las versiones anteriores a V14 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 y KTP900F (todas las versiones anteriores a V14), SIMATIC WinCC Runtime Advanced (todas las versiones anteriores a V14), SIMATIC WinCC Runtime Professional (todas las versiones anteriores a V14), SIMATIC WinCC (TIA Portal) (todas las versiones anteriores a V14) y SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (todas las versiones). • http://www.securityfocus.com/bid/105931 https://cert-portal.siemens.com/productcert/pdf/ssa-944083.pdf • CWE-20: Improper Input Validation CWE-113: Improper Neutralization of CRLF Sequences in HTTP Headers ('HTTP Request/Response Splitting') •

CVSS: 4.9EPSS: 0%CPEs: 6EXPL: 0

A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the "administrators" group to crash services by sending specially crafted messages to the DCOM interface. Se detectó una vulnerabilidad en SIMATIC WinCC (versión V7.3 anterior a Upd 11 y versión V7.4 anterior a SP1), SIMATIC WinCC Runtime Professional (versión V13 anterior a SP2 y versión V14 anterior a SP1), SIMATIC WinCC (TIA Portal) Professional (versión V13 anterior a SP2 y versión V14 anterior a SP1) de Siemens, eso podría permitir a un atacante remoto autenticado, quien es miembro del grupo de los "administrators" bloquear los servicios enviando mensajes especialmente diseñados a la interfaz DCOM. • http://www.securityfocus.com/bid/98368 https://cert-portal.siemens.com/productcert/pdf/ssa-523365.pdf https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf • CWE-20: Improper Input Validation CWE-787: Out-of-bounds Write •