Page 2 of 11 results (0.006 seconds)

CVSS: 5.4EPSS: 0%CPEs: 23EXPL: 0

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify particular parts of the device configuration via SNMP. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires system privileges and user interaction. An attacker could use the vulnerability to compromise confidentiality and the integrity of the affected system. • http://www.securityfocus.com/bid/108412 https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf https://www.us-cert.gov/ics/advisories/ICSA-19-134-09 • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) •

CVSS: 8.8EPSS: 0%CPEs: 23EXPL: 0

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Panels 4" - 22", SIMATIC HMI Comfort Outdoor Panels 7" 15" (todas las versiones anteriores a V14 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 y KTP900F (todas las versiones anteriores a V14), SIMATIC WinCC Runtime Advanced (todas las versiones anteriores a V14), SIMATIC WinCC Runtime Professional (todas las versiones anteriores a V14), SIMATIC WinCC (TIA Portal) (todas las versiones anteriores a V14) y SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (todas las versiones). • http://www.securityfocus.com/bid/105931 https://cert-portal.siemens.com/productcert/pdf/ssa-944083.pdf • CWE-20: Improper Input Validation CWE-113: Improper Neutralization of CRLF Sequences in HTTP Headers ('HTTP Request/Response Splitting') •

CVSS: 8.1EPSS: 0%CPEs: 23EXPL: 0

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Panels 4" - 22" (todas las versiones anteriores a V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" 15" (todas las versiones anteriores a V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 y KTP900F (todas las versiones anteriores a V15 Update 4), SIMATIC WinCC Runtime Advanced (todas las versiones anteriores a V15 Update 4), SIMATIC WinCC Runtime Professional (todas las versiones anteriores a V15 Update 4), SIMATIC WinCC (TIA Portal) (todas las versiones anteriores a V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (todas las versiones). • http://www.securityfocus.com/bid/105922 https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf • CWE-601: URL Redirection to Untrusted Site ('Open Redirect') •

CVSS: 7.5EPSS: 0%CPEs: 23EXPL: 0

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). A directory traversal vulnerability could allow to download arbitrary files from the device. The security vulnerability could be exploited by an attacker with network access to the integrated web server. No user interaction and no authentication is required to exploit the vulnerability. The vulnerability impacts the confidentiality of the device. • http://www.securityfocus.com/bid/105922 https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •

CVSS: 7.5EPSS: 0%CPEs: 48EXPL: 0

A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions < V8.1 Upd5), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd1), SIMATIC BATCH V7.1 and earlier (All versions), SIMATIC BATCH V8.0 (All versions < V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (All versions < V8.1 SP1 Upd16), SIMATIC BATCH V8.2 (All versions < V8.2 Upd10), SIMATIC BATCH V9.0 (All versions < V9.0 SP1), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions < 15 SP1), SIMATIC PCS 7 V7.1 and earlier (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP1), SIMATIC Route Control V7.1 and earlier (All versions), SIMATIC Route Control V8.0 (All versions), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Upd2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Upd5), SIMATIC WinCC V7.2 and earlier (All versions < WinCC 7.2 Upd 15), SIMATIC WinCC V7.3 (All versions < WinCC 7.3 Upd 16), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 4), SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). Specially crafted messages sent to the RPC service of the affected products could cause a Denial-of-Service condition on the remote and local communication functionality of the affected products. A reboot of the system is required to recover the remote and local communication functionality. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. • http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html https://cert-portal.siemens.com/productcert/pdf/ssa-348629.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf • CWE-20: Improper Input Validation •