Page 2 of 7 results (0.005 seconds)

CVSS: 7.5EPSS: 0%CPEs: 155EXPL: 0

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). • https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 • CWE-770: Allocation of Resources Without Limits or Throttling •

CVSS: 9.8EPSS: 1%CPEs: 28EXPL: 0

A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046) Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Panels (incl. • https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02 • CWE-306: Missing Authentication for Critical Function •