Page 2 of 17 results (0.006 seconds)

CVSS: 7.8EPSS: 0%CPEs: 10EXPL: 0

12 Dec 2018 — A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker could modify a user-writeable configuration file so that after reboot or manual initiation the system reloads the modified configuration file and attacker-controlled code is executed with elevated privileges. The security vulnera... • http://www.securityfocus.com/bid/106185 • CWE-693: Protection Mechanism Failure •

CVSS: 9.3EPSS: 1%CPEs: 6EXPL: 0

12 Dec 2018 — A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 5900/tcp. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the... • http://www.securityfocus.com/bid/106185 • CWE-190: Integer Overflow or Wraparound •

CVSS: 6.6EPSS: 0%CPEs: 10EXPL: 0

12 Dec 2018 — A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker with user privileges could use the service command application for privilege escalation to an elevated user but not root. The security vulnerability could be exploited by an attacker with local access to the affected systems. Suc... • http://www.securityfocus.com/bid/106185 • CWE-264: Permissions, Privileges, and Access Controls •

CVSS: 7.8EPSS: 0%CPEs: 10EXPL: 0

12 Dec 2018 — A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker with elevated user privileges (manufact) could modify a CRAMFS archive so that after reboot the system loads the modified CRAMFS file and attacker-controlled code is executed with root privileges. The security vulnerability could... • http://www.securityfocus.com/bid/106185 • CWE-693: Protection Mechanism Failure •

CVSS: 6.5EPSS: 0%CPEs: 26EXPL: 0

20 Mar 2018 — A vulnerability has been identified in SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC CP 343-1 (incl. SIPLUS variants) (All versions), SIMATIC CP 343-1 Advanced (incl. SIPLUS variants) (All versions), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 Advanced (All v... • https://cert-portal.siemens.com/productcert/pdf/ssa-592007.pdf • CWE-20: Improper Input Validation •

CVSS: 7.1EPSS: 0%CPEs: 181EXPL: 0

11 May 2017 — Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. This vulnerability affects only SIMATIC HMI Multi Panels and HMI Mobile Panels, and S7-300/S7-400 devices. Los paquetes PROFINET DCP especialmente diseñados que se envían en un segmento Ethernet local (capa 2) a un producto afectado podrían causar una condi... • http://www.securityfocus.com/bid/98369 • CWE-400: Uncontrolled Resource Consumption •

CVSS: 7.1EPSS: 0%CPEs: 209EXPL: 0

11 May 2017 — Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected. Los paquetes de difusión PROFINET DCP especialmente elaborados podrían causar una condición de denegación de servicio de los productos afectados en un segmento Ethernet local (capa 2). Se requiere la interacción humana para recuperar los sistemas. • http://www.securityfocus.com/bid/98369 • CWE-400: Uncontrolled Resource Consumption •