CVE-2018-11457
https://notcve.org/view.php?id=CVE-2018-11457
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated web server on port 4842/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 4842/tcp. Please note that this vulnerability is only exploitable if port 4842/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices on port 4842/tcp. Successful exploitation requires no privileges and no user interaction. • http://www.securityfocus.com/bid/106185 https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf • CWE-122: Heap-based Buffer Overflow •
CVE-2018-11461
https://notcve.org/view.php?id=CVE-2018-11461
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker with user privileges could use the service command application for privilege escalation to an elevated user but not root. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. • http://www.securityfocus.com/bid/106185 https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf • CWE-264: Permissions, Privileges, and Access Controls •
CVE-2018-11459
https://notcve.org/view.php?id=CVE-2018-11459
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker could modify a user-writeable configuration file so that after reboot or manual initiation the system reloads the modified configuration file and attacker-controlled code is executed with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. • http://www.securityfocus.com/bid/106185 https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf • CWE-693: Protection Mechanism Failure •
CVE-2018-11463
https://notcve.org/view.php?id=CVE-2018-11463
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A buffer overflow in the service command application could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. • http://www.securityfocus.com/bid/106185 https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer CWE-121: Stack-based Buffer Overflow •