Page 2 of 10 results (0.007 seconds)

CVSS: 9.3EPSS: 0%CPEs: 16EXPL: 0

The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication tokens for cookies, which makes it easier for remote attackers to bypass authentication via a crafted cookie. El servidor web HMI de Siemens WinCC flexible v2004, v2005, v2007 y v2008 antes de SP3, WinCC V11 (también conocido como TIA Portal) antes de SP2 Update 1, TP, OP, MP, Comfort Panels, y de los paneles de Mobile Panels SIMATIC HMI, WinCC V11 Advanced Runtime, y WinCC flexible Runtime genera tokens de autenticación para cookies, lo que hace que sea más fácil para los atacantes remotos a la hora de evitar la autenticación usando una cookie manipulada. • http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf • CWE-287: Improper Authentication •

CVSS: 5.0EPSS: 0%CPEs: 16EXPL: 0

CRLF injection vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via unspecified vectors. Vulnerabilidad de inyección CRLF en el servidor web HMI de Siemens WinCC flexible 2004, 2005, 2007 y 2008 anteriores a SP3; WinCC V11 (TIA portal) anteriores a SP2 Update 1; TP, OP, MP, Comfort Panels y Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; y WinCC flexible Runtime permite a atacantes remotos inyectar cabeceras HTTP arbitrarios y realizar ataques de división de respuesta HTTP a través de vectores sin especificar. • http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf • CWE-94: Improper Control of Generation of Code ('Code Injection') •

CVSS: 4.3EPSS: 0%CPEs: 16EXPL: 0

Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4510. Existe una vulnerabilidad de ejecución de comandos en sitios cruzados (XSS) en el servidor web HMI en Siemens WinCC flexible v2004, v2005, v2007 y v2008 antes de SP3, WinCC V11 (también conocido como TIA Portal) antes de SP2 Update 1, el TP, OP, MP, Comfort Panels, y los paneles de Mobile Panels SIMATIC HMI, WinCC V11 Runtime Advanced, y WinCC flexible Runtime. Esta vulnerabilidad permite a atacantes remotos inyectar secuencias de comandos web o HTML a través de vectores no especificados. Se trata de una vulnerabilidad diferente a CVE-2011-4510. • http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVSS: 7.8EPSS: 1%CPEs: 16EXPL: 2

Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to read arbitrary files via a ..%5c (dot dot backslash) in a URI. Vulnerabilidad de salto de directorio en miniweb.exe de servidor web HMI de Siemens WinCC flexible 2004, 2005, 2007, y 2008 anteriores a SP3; WinCC V11 (TIA portal) anteriores a SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime permite a atacantes remotos leer archivos arbitrarios a través de los caracteres ..%5c (punto punto barra invertida) en una URI. • https://www.exploit-db.com/exploits/18166 http://aluigi.org/adv/winccflex_1-adv.txt http://www.exploit-db.com/exploits/18166 http://www.osvdb.org/77383 http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf https • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •

CVSS: 8.5EPSS: 2%CPEs: 16EXPL: 2

miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a 0xfa character, which allows remote attackers to read data from arbitrary memory locations or cause a denial of service (application crash) via a crafted POST request. miniweb.exe del servidor web HMI de Siemens WinCC flexible 2004, 2005, 2007 y 2008 anteriores a SP3; WinCC V11 (portal TIA) anteriores a SP2 Update 1; los TP, OP, MP, Comfort Panels y Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; y WinCC flexible Runtime no manejan apropiadamente URIs que comienzan con un caracter 0xfa, lo que permite a atacantes remotos leer localizaciones de memoria arbitrarias o provocar una denegación de servicio (caída de la aplicación) a través de una petición POST. • https://www.exploit-db.com/exploits/18166 http://aluigi.org/adv/winccflex_1-adv.txt http://www.exploit-db.com/exploits/18166 http://www.osvdb.org/77384 http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf https • CWE-20: Improper Input Validation •