Page 2 of 11 results (0.005 seconds)

CVSS: 9.8EPSS: 0%CPEs: 2EXPL: 0

Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/saveParentControlInfo. • https://hackmd.io/%400dayResearch/rk8hQf5rh • CWE-787: Out-of-bounds Write •

CVSS: 7.8EPSS: 0%CPEs: 6EXPL: 1

An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router's web server (httpd). When processing the list parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow. Se descubrió un problema en los dispositivos Tenda AC7 con firmware a través de la versión V15.03.06.44_CN (AC7), dispositivos AC9 con firmware a través de la versión V15.03.05.19 (6318) _CN (AC9), y dispositivos AC10 con firmware a través de la versión V15.03.06.23_CN ( AC10). Existe una vulnerabilidad de desbordamiento de búfer en el servidor web del router (httpd). • https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-02/Tenda.md • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •

CVSS: 7.8EPSS: 0%CPEs: 6EXPL: 1

An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router's web server (httpd). When processing the page parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, a causing buffer overflow. Se descubrió un problema en los dispositivos Tenda AC7 con firmware a través de la versión V15.03.06.44_CN (AC7), dispositivos AC9 con firmware a través de la versión V15.03.05.19 (6318) _CN (AC9), y dispositivos AC10 con firmware a través de la versión V15.03.06.23_CN ( AC10). Existe una vulnerabilidad de desbordamiento de búfer en el servidor web del router (httpd). • https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-03/Tenda.md • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •

CVSS: 10.0EPSS: 94%CPEs: 6EXPL: 1

An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input. Se ha descubierto un problema en dispositivos Tenda AC7 con firmware hasta la versión V15.03.06.44_CN(AC7), dispositivos AC9 devices con firmware hasta la versión V15.03.05.19(6318)_CN(AC9) y dispositivos AC10 con firmware hasta la versión V15.03.06.23_CN(AC10). Una vulnerabilidad de inyección de comandos permite que los atacantes ejecuten comandos arbitrarios del sistema operativo mediante una petición goform/setUsbUnload. • https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/Tenda.md • CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') •

CVSS: 9.0EPSS: 2%CPEs: 4EXPL: 1

An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN and AC10 V15.03.06.23_CN devices. The mac parameter in a POST request is used directly in a doSystemCmd call, causing OS command injection. "Se ha descubierto un problema en dispositivos Tenda AC9 V15.03.05.19(6318)_CN y AC10 V15.03.06.23_CN. El parámetro mac en una petición POST se emplea directamente en una llamada doSystemCmd, provocando la inyección de comandos del sistema operativo." • https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-04/tenda.md • CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') •