CVE-2024-24488
https://notcve.org/view.php?id=CVE-2024-24488
An issue in Shenzen Tenda Technology CP3V2.0 V11.10.00.2311090948 allows a local attacker to obtain sensitive information via the password component. Un problema en Shenzen Tenda Technology CP3V2.0 V11.10.00.2311090948 permite a un atacante local obtener información confidencial a través del componente de contraseña. • https://github.com/minj-ae/CVE-2024-24488 • CWE-312: Cleartext Storage of Sensitive Information •
CVE-2024-0932 – Tenda AC10U setSmartPowerManagement stack-based overflow
https://notcve.org/view.php?id=CVE-2024-0932
A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.49_multi_TDE01. This issue affects the function setSmartPowerManagement. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. • https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/setSmartPowerManagement.md https://vuldb.com/?ctiid.252137 https://vuldb.com/?id.252137 • CWE-121: Stack-based Buffer Overflow •
CVE-2024-0931 – Tenda AC10U saveParentControlInfo stack-based overflow
https://notcve.org/view.php?id=CVE-2024-0931
A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49_multi_TDE01. This vulnerability affects the function saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. • https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/saveParentControlInfo_1.md https://vuldb.com/?ctiid.252136 https://vuldb.com/?id.252136 • CWE-121: Stack-based Buffer Overflow •
CVE-2024-0930 – Tenda AC10U fromSetWirelessRepeat stack-based overflow
https://notcve.org/view.php?id=CVE-2024-0930
A vulnerability classified as critical has been found in Tenda AC10U 15.03.06.49_multi_TDE01. This affects the function fromSetWirelessRepeat. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. • https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/fromSetWirelessRepeat.md https://vuldb.com/?ctiid.252135 https://vuldb.com/?id.252135 • CWE-121: Stack-based Buffer Overflow •
CVE-2024-0929 – Tenda AC10U fromNatStaticSetting stack-based overflow
https://notcve.org/view.php?id=CVE-2024-0929
A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. It has been rated as critical. Affected by this issue is the function fromNatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. • https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/fromNatStaticSetting.md https://vuldb.com/?ctiid.252134 https://vuldb.com/?id.252134 • CWE-121: Stack-based Buffer Overflow •