Page 20 of 750 results (0.006 seconds)

CVSS: 7.5EPSS: 0%CPEs: 1EXPL: 0

A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause all remote domains to access the resources (data) supplied by the server when an attacker sends a fetch request from third-party site or malicious site. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22) • https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf • CWE-668: Exposure of Resource to Wrong Sphere •

CVSS: 9.8EPSS: 0%CPEs: 12EXPL: 0

A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0) • https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf • CWE-521: Weak Password Requirements •

CVSS: 6.5EPSS: 0%CPEs: 2EXPL: 0

A CWE-1021: Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause an adversary to trick the interface user/admin into interacting with the application in an unintended way when the product does not implement restrictions on the ability to render within frames on external addresses. Affected Products: Conextâ„¢ ComBox (All Versions) Existe una vulnerabilidad CWE-1021: Restricción inadecuada de las capas o marcos de la interfaz de usuario renderizados que podría causar que un adversario engañe la interfaz user/admin para que interactúe con la aplicación de una manera no deseada cuando el producto no implementa restricciones en la capacidad de renderizar dentro de los marcos. en direcciones externas. Productos afectados: Conext? ComBox (todas las versiones) • https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-03_ConextCombox_Security_Notification.pdf • CWE-1021: Improper Restriction of Rendered UI Layers or Frames •

CVSS: 9.8EPSS: 0%CPEs: 108EXPL: 0

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions), Modicon Momentum Unity M1E Processor - 171CBU* (All Versions), Modicon MC80 - BMKC80 (All Versions), Legacy Modicon Quantum - 140CPU65* and Premium CPUs - TSXP57* (All Versions) • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-010-05_Modicon_Controllers_Security_Notification.pdf • CWE-754: Improper Check for Unusual or Exceptional Conditions •

CVSS: 9.1EPSS: 0%CPEs: 1EXPL: 0

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause access to manipulate and read specific files in the IGSS project report directory, potentially leading to a denial-of-service condition when an attacker sends specific messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-165-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-01_IGSS_Security_Notification.pdf • CWE-306: Missing Authentication for Critical Function •