Page 21 of 143 results (0.006 seconds)

CVSS: 7.8EPSS: 0%CPEs: 8EXPL: 0

A vulnerability in the CLI of Cisco Firepower Threat Defense (FTD) Software could allow an authenticated, local attacker to perform a command injection attack. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by injecting commands into arguments for a specific command. A successful exploit could allow the attacker to execute commands with root privileges. "Una vulnerabilidad en la CLI del software Firepower Threat Defense (FTD) de Cisco podría permitir a un atacante local identificado ejecutar un ataque de inyección de comando. • http://www.securityfocus.com/bid/108156 https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190501-frpwr-cmd-inj • CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') •

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

A vulnerability in the CLI of Cisco Firepower Threat Defense (FTD) Software could allow an authenticated, local attacker to perform a command injection attack. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by injecting commands into arguments for a specific command. A successful exploit could allow the attacker to execute commands with root privileges. Una vulnerabilidad en la CLI del software Firepower Threat Defense (FTD) de Cisco, podría permitir a un atacante local identificado ejecutar un ataque de inyección de comando. • https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190501-ftd-cmd-inject • CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') •

CVSS: 7.5EPSS: 0%CPEs: 7EXPL: 0

Multiple vulnerabilities in the Server Message Block (SMB) Protocol preprocessor detection engine for Cisco Firepower Threat Defense (FTD) Software could allow an unauthenticated, adjacent or remote attacker to cause a denial of service (DoS) condition. For more information about these vulnerabilities, see the Details section of this advisory. Múltiples vulnerabilidades en el motor de detección del preprocesador del Protocolo Server Message Block (SMB) para el software Firepower Threat Defense (FTD) Cisco, podrían permitir a un atacante no identificado, adyacente o remoto, causar una condición de Denegación de Servicio (DoS). Para más información sobre estas vulnerabilidades, consulte la sección Detalles de este aviso. • http://www.securityfocus.com/bid/108171 https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190501-frpwr-smb-snort • CWE-400: Uncontrolled Resource Consumption •

CVSS: 4.8EPSS: 0%CPEs: 3EXPL: 0

A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) could allow an authenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the web-based management interface of an affected system. The vulnerability is due to insufficient validation of user-supplied input in the web-based management interface of the affected system. An attacker could exploit this vulnerability by persuading a user to access a report containing malicious content. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information. Versions 6.2.3, 6.3.0, and 6.4.0 are affected. • http://www.securityfocus.com/bid/107995 https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190417-cfmc-xss • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVSS: 6.1EPSS: 0%CPEs: 7EXPL: 0

A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the web-based management interface of an affected system. The vulnerability is due to insufficient validation of user-supplied input by the web-based management interface of the affected system. An attacker could exploit this vulnerability by persuading a user of the interface to click a maliciously crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information. Una vulnerabilidad en la interfaz de gestión web de Cisco Firepower Management Center (FMC) podría permitir que un atacante remoto no autenticado lleve a cabo un ataque de Cross-Site Scripting (XSS) contra un usuario de dicha interfaz en el sistema afectado. • http://www.securityfocus.com/bid/106927 https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190206-fmc-xss • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •