Page 23 of 547 results (0.008 seconds)

CVSS: 8.0EPSS: 0%CPEs: 142EXPL: 0

A reflected Cross-site Scripting (XSS) vulnerability in J-Web of Juniper Networks Junos OS allows a network-based authenticated attacker to run malicious scripts reflected off J-Web to the victim's browser in the context of their session within J-Web. This may allow the attacker to gain control of the device or attack other authenticated user sessions. This issue affects: Juniper Networks Junos OS All versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R3-S9; 19.1 versions prior to 19.1R3-S6; 19.2 versions prior to 19.2R3-S3; 19.3 versions prior to 19.3R2-S6, 19.3R3-S3; 19.4 versions prior to 19.4R3-S5; 20.1 versions prior to 20.1R3-S4; 20.2 versions prior to 20.2R3-S2; 20.3 versions prior to 20.3R3; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R1-S1, 21.1R2. Una vulnerabilidad de tipo Cross-site Scripting (XSS) reflejado en J-Web de Juniper Networks Junos OS permite a un atacante autenticado basado en la red ejecutar scripts maliciosas reflejadas desde J-Web al navegador de la víctima en el contexto de su sesión dentro de J-Web. Esto puede permitir al atacante obtener el control del dispositivo o atacar otras sesiones de usuarios autenticados. • https://kb.juniper.net/JSA69517 • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVSS: 6.8EPSS: 0%CPEs: 166EXPL: 0

BIND 9.11.0 -> 9.11.36 9.12.0 -> 9.16.26 9.17.0 -> 9.18.0 BIND Supported Preview Editions: 9.11.4-S1 -> 9.11.36-S1 9.16.8-S1 -> 9.16.26-S1 Versions of BIND 9 earlier than those shown - back to 9.1.0, including Supported Preview Editions - are also believed to be affected but have not been tested as they are EOL. The cache could become poisoned with incorrect records leading to queries being made to the wrong servers, which might also result in false information being returned to clients. BIND versiones 9.11.0 posteriores a 9.11.36, versiones 9.12.0 posteriores a 9.16.26, versiones 9.17.0 posteriores a 9.18.0, Ediciones Preliminares Soportadas con BIND: versiones .11.4-S1 posteriores a 9.11.36-S1, versiones 9.16.8-S1 posteriores a 9.16.26-S1, también creemos que las versiones de BIND 9 anteriores a las mostradas - hasta la versión 9.1.0, incluyendo las ediciones preliminares soportadas - también están afectadas pero no han sido probadas ya que son EOL. La caché podría envenenarse con registros incorrectos, conllevando a una realización de consultas a servidores erróneos, lo que también podría resultar en que se devolviera información falsa a clientes A cache poisoning vulnerability was found in BIND when using forwarders. Bogus NS records supplied by the forwarders may be cached and used by name if it needs to recurse for any reason. • https://cert-portal.siemens.com/productcert/pdf/ssa-637483.pdf https://kb.isc.org/v1/docs/cve-2021-25220 https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/2SXT7247QTKNBQ67MNRGZD23ADXU6E5U https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/5VX3I2U3ICOIEI5Y7OYA6CHOLFMNH3YQ https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/API7U5E7SX7BAAVFNW366FFJGD6NZZKV https://lists.fedoraproject.org/archives/list/package-announc • CWE-444: Inconsistent Interpretation of HTTP Requests ('HTTP Request/Response Smuggling') •

CVSS: 7.5EPSS: 0%CPEs: 138EXPL: 0

An Improper Check for Unusual or Exceptional Conditions vulnerability in the processing of specific IPv6 packets on certain EX Series devices may lead to exhaustion of DMA memory causing a Denial of Service (DoS). Over time, exploitation of this vulnerability may cause traffic to stop being forwarded, or a crash of the fxpc process. An indication of the issue occurring may be observed through the following log messages: Sep 13 17:14:59 hostname : %PFE-3: fpc0 (buf alloc) failed allocating packet buffer Sep 13 17:14:59 hostname : %PFE-7: fpc0 brcm_pkt_buf_alloc:393 (buf alloc) failed allocating packet buffer When Packet DMA heap utilization reaches 99%, the system will become unstable. Packet DMA heap utilization can be monitored using the command: user@junos# request pfe execute target fpc0 timeout 30 command "show heap" ID Base Total(b) Free(b) Used(b) % Name -- ---------- ----------- ----------- ----------- --- ----------- 0 213301a8 536870488 387228840 149641648 27 Kernel 1 91800000 8388608 3735120 4653488 55 DMA 2 92000000 75497472 74452192 1045280 1 PKT DMA DESC 3 d330000 335544320 257091400 78452920 23 Bcm_sdk 4 96800000 184549376 2408 184546968 99 Packet DMA <<<< 5 903fffe0 20971504 20971504 0 0 Blob This issue affects: Juniper Networks Junos OS 18.4 versions prior to 18.4R2-S10, 18.4R3-S10 on EX2300 Series, EX2300-MP Series, EX3400 Series; 19.1 versions prior to 19.1R3-S7 on EX2300 Series, EX2300-MP Series, EX3400 Series; 19.2 versions prior to 19.2R1-S8, 19.2R3-S4 on EX2300 Series, EX2300-MP Series, EX3400 Series; 19.3 versions prior to 19.3R3-S5 on EX2300 Series, EX2300-MP Series, EX3400 Series; 19.4 versions prior to 19.4R3-S7 on EX2300 Series, EX2300-MP Series, EX3400 Series; 20.1 versions prior to 20.1R3-S3 on EX2300 Series, EX2300-MP Series, EX3400 Series; 20.2 versions prior to 20.2R3-S3 on EX2300 Series, EX2300-MP Series, EX3400 Series; 20.3 versions prior to 20.3R3-S2 on EX2300 Series, EX2300-MP Series, EX3400 Series; 20.4 versions prior to 20.4R3-S1 on EX2300 Series, EX2300-MP Series, EX3400 Series; 21.1 versions prior to 21.1R2-S2, 21.1R3 on EX2300 Series, EX2300-MP Series, EX3400 Series; 21.2 versions prior to 21.2R1-S2, 21.2R2 on EX2300 Series, EX2300-MP Series, EX3400 Series; 21.3 versions prior to 21.3R1-S1, 21.3R2 on EX2300 Series, EX2300-MP Series, EX3400 Series. Una vulnerabilidad de Comprobación inapropiada de Condiciones Inusuales o Excepcionales en el procesamiento de paquetes IPv6 específicos en determinados dispositivos de la serie EX puede conllevar a un agotamiento de la memoria DMA causando una denegación de servicio (DoS). • https://kb.juniper.net/JSA11286 • CWE-754: Improper Check for Unusual or Exceptional Conditions •

CVSS: 6.5EPSS: 0%CPEs: 222EXPL: 0

A Improper Validation of Specified Index, Position, or Offset in Input vulnerability in the Juniper DHCP daemon (jdhcpd) of Juniper Networks Junos OS allows an adjacent unauthenticated attacker to cause a crash of jdhcpd and thereby a Denial of Service (DoS). In a scenario where DHCP relay or local server is configured the problem can be triggered if a DHCPv4 packet with specific options is received leading to a corruption of the options read from the packet. This corruption can then lead to jdhcpd crash and restart. This issue affects: Juniper Networks Junos OS 17.4R1 and later versions prior to 18.4R3-S10; 19.1 versions prior to 19.1R3-S7; 19.2 versions prior to 19.2R1-S8, 19.2R3-S4; 19.3 versions prior to 19.3R3-S4; 19.4 versions prior to 19.4R3-S6; 20.1 versions prior to 20.1R3-S2; 20.2 versions prior to 20.2R3-S3; 20.3 versions prior to 20.3R3-S2; 20.4 versions prior to 20.4R3-S1; 21.1 versions prior to 21.1R2-S2, 21.1R3; 21.2 versions prior to 21.2R1-S2, 21.2R2, 21.2R3; 21.3 versions prior to 21.3R1-S1, 21.3R2. Una vulnerabilidad de comprobación inapropiada de Índice, Posición o Desplazamiento Especificado en la Entrada en el demonio DHCP de Juniper (jdhcpd) del Sistema Operativo Junos de Juniper Networks permite a un atacante adyacente no autenticado causar un bloqueo de jdhcpd y por lo tanto una Denegación de Servicio (DoS). • https://kb.juniper.net/JSA11285 • CWE-20: Improper Input Validation •

CVSS: 7.5EPSS: 0%CPEs: 236EXPL: 0

A release of illegal memory vulnerability in the snmpd daemon of Juniper Networks Junos OS, Junos OS Evolved allows an attacker to halt the snmpd daemon causing a sustained Denial of Service (DoS) to the service until it is manually restarted. This issue impacts any version of SNMP – v1,v2, v3 This issue affects: Juniper Networks Junos OS 12.3 versions prior to 12.3R12-S20; 15.1 versions prior to 15.1R7-S11; 18.3 versions prior to 18.3R3-S6; 18.4 versions prior to 18.4R2-S9, 18.4R3-S10; 19.1 versions prior to 19.1R2-S3, 19.1R3-S7; 19.2 versions prior to 19.2R1-S8, 19.2R3-S4; 19.3 versions prior to 19.3R3-S4; 19.4 versions prior to 19.4R2-S5, 19.4R3-S6; 20.1 versions prior to 20.1R3-S2; 20.2 versions prior to 20.2R3-S3; 20.3 versions prior to 20.3R3-S1; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R2-S2, 21.1R3; 21.2 versions prior to 21.2R1-S2, 21.2R2. Juniper Networks Junos OS Evolved 21.2 versions prior to 21.2R3-EVO; 21.3 versions prior to 21.3R2-EVO. Una vulnerabilidad de liberación de memoria ilegal en el demonio snmpd de Juniper Networks Junos OS, Junos OS Evolved permite a un atacante detener el demonio snmpd causando una denegación de servicio (DoS) sostenida al servicio hasta que sea reiniciada manualmente. Este problema afecta a cualquier versión de SNMP: v1, v2, v3: Juniper Networks Junos OS 12.3 versiones anteriores a 12.3R12-S20; 15.1 versiones anteriores a 15.1R7-S11; 18.3 versiones anteriores a 18.3R3-S6; 18.4 versiones anteriores a 18.4R2-S9, 18.4R3-S10; 19.1 versiones anteriores a 19.1R2-S3, 19.1R3-S7; 19.2 versiones anteriores a 19.2R1-S8, 19.2R3-S4; 19. 3 versiones anteriores a 19.3R3-S4; 19.4 versiones anteriores a 19.4R2-S5, 19.4R3-S6; 20.1 versiones anteriores a 20.1R3-S2; versiones 20.2 anteriores a 20.2R3-S3; versiones 20.3 anteriores a 20.3R3-S1; versiones 20.4 anteriores a 20.4R3; versiones 21.1 anteriores a 21.1R2-S2, 21.1R3; 21.2 versiones anteriores a 21.2R1-S2, 21.2R2. • https://kb.juniper.net/JSA11283 https://www.juniper.net/documentation/us/en/software/junos/network-mgmt/topics/ref/statement/client-list-edit-snmp.html • CWE-755: Improper Handling of Exceptional Conditions •