Page 23 of 133 results (0.003 seconds)

CVSS: 7.8EPSS: 0%CPEs: 4EXPL: 0

An issue was discovered in Open Design Alliance Drawings SDK before 2021.12. A memory corruption vulnerability exists when reading malformed DGN files. It can allow attackers to cause a crash, potentially enabling denial of service (Crash, Exit, or Restart). Se detectó un problema en Open Design Alliance Drawings SDK versiones anteriores a 2021.12. Se presenta una vulnerabilidad de corrupción de la memoria al leer archivos DGN malformados. • https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf https://www.opendesign.com/security-advisories https://www.zerodayinitiative.com/advisories/ZDI-21-226 • CWE-787: Out-of-bounds Write •

CVSS: 7.8EPSS: 0%CPEs: 4EXPL: 0

An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A Type Conversion issue exists when rendering malformed .DXF and .DWG files. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart). Se detectó un problema en el SDK de dibujos de Open Design Alliance anterior a la versión 2021.11. Existe un problema de conversión de tipos al renderizar archivos .DXF y .DWG malformados. • https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf https://www.opendesign.com/security-advisories https://www.zerodayinitiative.com/advisories/ZDI-21-218 https://www.zerodayinitiative.com/advisories/ZDI-21-223 https://www.zerodayinitiative.com/advisories/ZDI-21-224 https://www.zerodayinitiative.com/advisories/ZDI-21-244 https://www.zerodayinitiative.com/advisories/ZDI-21-245 https://www.zerodayinitiative.com/advisories/ZDI-2 • CWE-704: Incorrect Type Conversion or Cast •

CVSS: 7.8EPSS: 0%CPEs: 4EXPL: 0

An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A NULL pointer dereference exists when rendering malformed .DXF and .DWG files. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart). Se detectó un problema en el SDK de dibujos de Open Design Alliance anterior a la versión 2021.11. Existe una derivación de puntero nulo al renderizar archivos .DXF y .DWG malformados. • https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf https://www.opendesign.com/security-advisories https://www.zerodayinitiative.com/advisories/ZDI-21-221 https://www.zerodayinitiative.com/advisories/ZDI-21-222 • CWE-476: NULL Pointer Dereference •

CVSS: 7.8EPSS: 0%CPEs: 4EXPL: 0

An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A Type Confusion issue exists when rendering malformed .DXF and .DWG files. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart). Se detectó un problema en el SDK de dibujos de Open Design Alliance anterior a la versión 2021.11. Existe un problema de confusión de tipos al renderizar archivos .DXF y .DWG malformados. • https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf https://www.opendesign.com/security-advisories https://www.zerodayinitiative.com/advisories/ZDI-21-219 • CWE-843: Access of Resource Using Incompatible Type ('Type Confusion') •

CVSS: 7.8EPSS: 0%CPEs: 4EXPL: 0

An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A stack-based buffer overflow vulnerability exists when the recover operation is run with malformed .DXF and .DWG files. This can allow attackers to cause a crash potentially enabling a denial of service attack (Crash, Exit, or Restart) or possible code execution. Se detectó un problema en Open Design Alliance Drawings SDK versiones anteriores a 2021.11. Se presenta una vulnerabilidad de desbordamiento del búfer en la región stack de la memoria cuando la operación de recuperación se ejecuta con archivos .DXF y .DWG malformados. • https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf https://www.opendesign.com/security-advisories https://www.zerodayinitiative.com/advisories/ZDI-21-220 https://www.zerodayinitiative.com/advisories/ZDI-21-240 https://www.zerodayinitiative.com/advisories/ZDI-21-243 • CWE-787: Out-of-bounds Write •