Page 25 of 133 results (0.007 seconds)

CVSS: 8.8EPSS: 0%CPEs: 2EXPL: 0

A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing of CG4 files. This could result in a memory access past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12027) Se ha identificado una vulnerabilidad en JT2Go (todas las versiones anteriores a V13.1.0), Teamcenter Visualization (todas las versiones anteriores a V13.1.0). • https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf https://www.zerodayinitiative.com/advisories/ZDI-21-062 • CWE-125: Out-of-bounds Read •

CVSS: 7.8EPSS: 0%CPEs: 5EXPL: 0

A vulnerability has been identified in JT2Go (All versions < V13.1.0.1), Solid Edge SE2020 (All Versions < SE2020MP12), Solid Edge SE2021 (All Versions < SE2021MP2), Teamcenter Visualization (All versions < V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11892) Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones anteriores a V13.1.0.1), Solid Edge SE2020 (Todas las versiones anteriores a SE2020MP12), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP2), Teamcenter Visualization (Todas las versiones anteriores a V13.1.0.1). • https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf https://www.zerodayinitiative.com/advisories/ZDI-21-050 • CWE-121: Stack-based Buffer Overflow CWE-787: Out-of-bounds Write •

CVSS: 8.8EPSS: 5%CPEs: 2EXPL: 0

A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing of TGA files. This could lead to a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12016, ZDI-CAN-12017) Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones anteriores a V13.1.0), Teamcenter Visualization (Todas las versiones anteriores a V13.1.0). • https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf https://www.zerodayinitiative.com/advisories/ZDI-21-059 https://www.zerodayinitiative.com/advisories/ZDI-21-061 • CWE-122: Heap-based Buffer Overflow CWE-787: Out-of-bounds Write •

CVSS: 8.8EPSS: 0%CPEs: 2EXPL: 0

A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing CG4 and CGM files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11898) Se ha identificado una vulnerabilidad en JT2Go (todas las versiones anteriores a V13.1.0), Teamcenter Visualization (todas las versiones anteriores a V13.1.0). • https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf https://www.zerodayinitiative.com/advisories/ZDI-21-052 • CWE-787: Out-of-bounds Write •

CVSS: 8.8EPSS: 0%CPEs: 2EXPL: 0

A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11891) Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones anteriores a V13.1.0), Teamcenter Visualization (Todas las versiones anteriores a V13.1.0). • https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf https://www.zerodayinitiative.com/advisories/ZDI-21-049 • CWE-787: Out-of-bounds Write •