Page 27 of 296 results (0.016 seconds)

CVSS: 6.5EPSS: 0%CPEs: 219EXPL: 0

An Exposure of System Data vulnerability in Juniper Networks Junos OS and Junos OS Evolved, where a sensitive system-level resource is not being sufficiently protected, allows a network-based unauthenticated attacker to send specific traffic which partially reaches this resource. A high rate of specific traffic may lead to a partial Denial of Service (DoS) as the CPU utilization of the RE is significantly increased. The SNMP Agent Extensibility (agentx) process should only be listening to TCP port 705 on the internal routing instance. External connections destined to port 705 should not be allowed. This issue affects: Juniper Networks Junos OS: 15.1 versions prior to 15.1R7-S9; 17.3 versions prior to 17.3R3-S12; 17.4 versions prior to 17.4R2-S13, 17.4R3-S5; 18.3 versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R2-S8; 19.1 versions prior to 19.1R3-S5; 19.2 versions prior to 19.2R3-S2; 19.3 versions prior to 19.3R2-S6, 19.3R3-S2; 19.4 versions prior to 19.4R1-S4, 19.4R2-S4, 19.4R3; 20.1 versions prior to 20.1R2; 20.2 versions prior to 20.2R2; 20.3 versions prior to 20.3R2. • https://kb.juniper.net/JSA11193 • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor CWE-497: Exposure of Sensitive System Information to an Unauthorized Control Sphere •

CVSS: 6.5EPSS: 0%CPEs: 222EXPL: 0

Improper Handling of Exceptional Conditions in Ethernet interface frame processing of Juniper Networks Junos OS allows an attacker to send specially crafted frames over the local Ethernet segment, causing the interface to go into a down state, resulting in a Denial of Service (DoS) condition. The interface does not recover on its own and the FPC must be reset manually. Continued receipt and processing of these frames will create a sustained Denial of Service (DoS) condition. This issue is platform-specific and affects the following platforms and line cards: * MPC7E/8E/9E and MPC10E on MX240, MX480, MX960, MX2008, MX2010, and MX2020 * MX204, MX10003, MX10008, MX10016 * EX9200, EX9251 * SRX4600 No other products or platforms are affected by this vulnerability. An indication of this issue occurring can be seen in the system log messages, as shown below: user@host> show log messages | match "Failed to complete DFE tuning" fpc4 smic_phy_dfe_tuning_state: et-4/1/6 - Failed to complete DFE tuning (count 3) and interface will be in a permanently down state: user@host> show interfaces et-4/1/6 terse Interface Admin Link Proto Local Remote et-4/1/6 up down et-4/1/6.0 up down aenet --> ae101.0 This issue affects Juniper Networks Junos OS: 16.1 versions prior to 16.1R7-S7 on MX Series; 17.1R1 and later versions prior to 17.2R3-S3 on MX Series; 17.3 versions prior to 17.3R3-S8 on MX Series; 17.4 versions prior to 17.4R2-S11, 17.4R3-S1 on MX Series, SRX4600; 18.1 versions prior to 18.1R3-S10 on MX Series, EX9200 Series, SRX4600; 18.2 versions prior to 18.2R3-S3 on MX Series, EX9200 Series, SRX4600; 18.3 versions prior to 18.3R3-S1 on MX Series, EX9200 Series, SRX4600; 18.4 versions prior to 18.4R2-S3, 18.4R3 on MX Series, EX9200 Series, SRX4600; 19.1 versions prior to 19.1R2-S1, 19.1R3 on MX Series, EX9200 Series, SRX4600; 19.2 versions prior to 19.2R1-S3, 19.2R2 on MX Series, EX9200 Series, SRX4600; 19.3 versions prior to 19.3R2 on MX Series, EX9200 Series, SRX4600. • https://kb.juniper.net/JSA11192 • CWE-755: Improper Handling of Exceptional Conditions •

CVSS: 6.5EPSS: 0%CPEs: 359EXPL: 0

When user-defined ARP Policer is configured and applied on one or more Aggregated Ethernet (AE) interface units, a Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability between the Device Control Daemon (DCD) and firewall process (dfwd) daemons of Juniper Networks Junos OS allows an attacker to bypass the user-defined ARP Policer. In this particular case the User ARP policer is replaced with default ARP policer. To review the desired ARP Policers and actual state one can run the command "show interfaces <> extensive" and review the output. See further details below. An example output is: show interfaces extensive | match policer Policer: Input: __default_arp_policer__ <<< incorrect if user ARP Policer was applied on an AE interface and the default ARP Policer is displayed Policer: Input: jtac-arp-ae5.317-inet-arp <<< correct if user ARP Policer was applied on an AE interface For all platforms, except SRX Series: This issue affects Juniper Networks Junos OS: All versions 5.6R1 and all later versions prior to 18.4 versions prior to 18.4R2-S9, 18.4R3-S9 with the exception of 15.1 versions 15.1R7-S10 and later versions; 19.4 versions prior to 19.4R3-S3; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R3-S2; 20.3 version 20.3R1 and later versions; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R2; This issue does not affect Juniper Networks Junos OS versions prior to 5.6R1. • https://kb.juniper.net/JSA11191 • CWE-367: Time-of-check Time-of-use (TOCTOU) Race Condition •

CVSS: 6.5EPSS: 0%CPEs: 227EXPL: 0

A vulnerability in the processing of specific MPLS packets in Juniper Networks Junos OS on MX Series and EX9200 Series devices with Trio-based MPCs (Modular Port Concentrators) may cause FPC to crash and lead to a Denial of Service (DoS) condition. Continued receipt of this packet will sustain the Denial of Service (DoS) condition. This issue only affects MX Series and EX9200 Series with Trio-based PFEs (Packet Forwarding Engines). This issue affects Juniper Networks Junos OS on MX Series, EX9200 Series: 17.3 versions prior to 17.3R3-S12; 17.4 versions prior to 17.4R2-S13, 17.4R3-S5; 18.1 versions prior to 18.1R3-S13; 18.2 versions prior to 18.2R3-S8; 18.3 versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R2-S8, 18.4R3-S8; 19.1 versions prior to 19.1R3-S5; 19.2 versions prior to 19.2R3-S2; 19.3 versions prior to 19.3R2-S6, 19.3R3-S3; 19.4 versions prior to 19.4R1-S4, 19.4R2-S4, 19.4R3-S2; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R2-S2, 20.2R3; 20.3 versions prior to 20.3R2; 20.4 versions prior to 20.4R2; Una vulnerabilidad en el procesamiento de paquetes MPLS específicos en Juniper Networks Junos OS en dispositivos de las series MX y EX9200 con MPC (Modular Port Concentrators) basados en Trio puede causar a FPC bloquearse y conllevar a una condición de Denegación de Servicio (DoS). Una recepción continua de este paquete mantendrá la condición de Denegación de Servicio (DoS). • https://kb.juniper.net/JSA11190 • CWE-754: Improper Check for Unusual or Exceptional Conditions •

CVSS: 7.5EPSS: 0%CPEs: 255EXPL: 0

An uncontrolled resource consumption vulnerability in Juniper Networks Junos OS on QFX5000 Series and EX4600 Series switches allows an attacker sending large amounts of legitimate traffic destined to the device to cause Interchassis Control Protocol (ICCP) interruptions, leading to an unstable control connection between the Multi-Chassis Link Aggregation Group (MC-LAG) nodes which can in turn lead to traffic loss. Continued receipt of this amount of traffic will create a sustained Denial of Service (DoS) condition. An indication that the system could be impacted by this issue is the following log message: "DDOS_PROTOCOL_VIOLATION_SET: Warning: Host-bound traffic for protocol/exception LOCALNH:aggregate exceeded its allowed bandwidth at fpc <fpc number> for <n> times, started at <timestamp>" This issue affects Juniper Networks Junos OS on QFX5000 Series and EX4600 Series: 15.1 versions prior to 15.1R7-S9; 17.3 versions prior to 17.3R3-S11; 17.4 versions prior to 17.4R2-S13, 17.4R3-S5; 18.3 versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R2-S8, 18.4R3-S7; 19.1 versions prior to 19.1R3-S5; 19.2 versions prior to 19.2R1-S6, 19.2R3-S2; 19.3 versions prior to 19.3R2-S6, 19.3R3-S2; 19.4 versions prior to 19.4R1-S4, 19.4R2-S4, 19.4R3-S2; 20.1 versions prior to 20.1R2-S2, 20.1R3; 20.2 versions prior to 20.2R2-S3, 20.2R3; 20.3 versions prior to 20.3R2; 20.4 versions prior to 20.4R1-S1, 20.4R2. Una vulnerabilidad de consumo No Controlado de recursos en Juniper Networks Junos OS en los switches de las series QFX5000 y EX4600, permite a un atacante enviar grandes cantidades de tráfico legítimo destinado al dispositivo y causar interrupciones en Control Protocol (ICCP), conllevando a una conexión de control inestable entre los Nodos Multi-Chassis Link Aggregation Group (MC-LAG) que, a su vez, puede conllevar a pérdida de tráfico. Una recepción continua de esta cantidad de tráfico creará una condición de Denegación de Servicio (DoS) sostenida. • https://kb.juniper.net/JSA11187 • CWE-400: Uncontrolled Resource Consumption CWE-770: Allocation of Resources Without Limits or Throttling •