Page 27 of 271 results (0.008 seconds)

CVSS: 9.8EPSS: 0%CPEs: 277EXPL: 0

A vulnerability in the HTTP/HTTPS service used by J-Web, Web Authentication, Dynamic-VPN (DVPN), Firewall Authentication Pass-Through with Web-Redirect, and Zero Touch Provisioning (ZTP) allows an unauthenticated attacker to perform local file inclusion (LFI) or path traversal. Using this vulnerability, an attacker may be able to inject commands into the httpd.log, read files with 'world' readable permission file or obtain J-Web session tokens. In the case of command injection, as the HTTP service runs as user 'nobody', the impact of this command injection is limited. (CVSS score 5.3, vector CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N) In the case of reading files with 'world' readable permission, in Junos OS 19.3R1 and above, the unauthenticated attacker would be able to read the configuration file. (CVSS score 5.9, vector CVSS:3.1/ AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N) If J-Web is enabled, the attacker could gain the same level of access of anyone actively logged into J-Web. • https://kb.juniper.net/JSA11021 • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') CWE-73: External Control of File Name or Path •

CVSS: 7.5EPSS: 0%CPEs: 124EXPL: 0

When an attacker sends a specific crafted Ethernet Operation, Administration, and Maintenance (Ethernet OAM) packet to a target device, it may improperly handle the incoming malformed data and fail to sanitize this incoming data resulting in an overflow condition. This overflow condition in Juniper Networks Junos OS allows an attacker to cause a Denial of Service (DoS) condition by coring the CFM daemon. Continued receipt of these packets may cause an extended Denial of Service condition. This issue affects: Juniper Networks Junos OS 12.3 versions prior to 12.3R12-S15; 12.3X48 versions prior to 12.3X48-D95 on SRX Series; 14.1X50 versions prior to 14.1X50-D145; 14.1X53 versions prior to 14.1X53-D47; 15.1 versions prior to 15.1R2; 15.1X49 versions prior to 15.1X49-D170 on SRX Series; 15.1X53 versions prior to 15.1X53-D67. Cuando un atacante envía un paquete diseñado específico de Ethernet Operation, Administration, and Maintenance (Ethernet OAM) hacia un dispositivo objetivo, puede manejar inapropiadamente los datos malformados entrantes y presentar un fallo al sanear estos datos entrantes, resultando en una condición de desbordamiento. • https://kb.juniper.net • CWE-703: Improper Check or Handling of Exceptional Conditions CWE-755: Improper Handling of Exceptional Conditions •

CVSS: 7.2EPSS: 0%CPEs: 142EXPL: 0

A vulnerability in Juniper Networks SRX Series device configured as a Junos OS Enforcer device may allow a user to access network resources that are not permitted by a UAC policy. This issue might occur when the IP address range configured in the Infranet Controller (IC) is configured as an IP address range instead of an IP address/netmask. See the Workaround section for more detail. The Junos OS Enforcer CLI settings are disabled by default. This issue affects Juniper Networks Junos OS on SRX Series: 12.3X48 versions prior to 12.3X48-D100; 15.1X49 versions prior to 15.1X49-D210; 17.3 versions prior to 17.3R2-S5, 17.3R3-S8; 17.4 versions prior to 17.4R2-S9, 17.4R3-S1; 18.1 versions prior to 18.1R3-S10; 18.2 versions prior to 18.2R2-S7, 18.2R3-S3; 18.3 versions prior to 18.3R1-S7, 18.3R3-S2; 18.4 versions prior to 18.4R1-S6, 18.4R2-S4, 18.4R3-S1; 19.1 versions prior to 19.1R1-S4, 19.1R2-S1, 19.1R3; 19.2 versions prior to 19.2R1-S3, 19.2R2; 19.3 versions prior to 19.3R2-S1, 19.3R3; 19.4 versions prior to 19.4R1-S1, 19.4R2. • https://kb.juniper.net/JSA11018 • CWE-287: Improper Authentication CWE-288: Authentication Bypass Using an Alternate Path or Channel •

CVSS: 5.5EPSS: 0%CPEs: 288EXPL: 0

A privilege escalation vulnerability in Juniper Networks Junos OS devices configured with dual Routing Engines (RE), Virtual Chassis (VC) or high-availability cluster may allow a local authenticated low-privileged user with access to the shell to perform unauthorized configuration modification. This issue does not affect Junos OS device with single RE or stand-alone configuration. This issue affects Juniper Networks Junos OS 12.3 versions prior to 12.3R12-S14; 12.3X48 versions prior to 12.3X48-D86, 12.3X48-D90; 14.1X53 versions prior to 14.1X53-D51; 15.1 versions prior to 15.1R7-S6; 15.1X49 versions prior to 15.1X49-D181, 15.1X49-D190; 15.1X53 versions prior to 15.1X53-D592; 16.1 versions prior to 16.1R4-S13, 16.1R7-S6; 16.2 versions prior to 16.2R2-S10; 17.1 versions prior to 17.1R2-S11, 17.1R3-S1; 17.2 versions prior to 17.2R1-S9, 17.2R3-S3; 17.3 versions prior to 17.3R3-S6; 17.4 versions prior to 17.4R2-S6, 17.4R3; 18.1 versions prior to 18.1R3-S7; 18.2 versions prior to 18.2R2-S5, 18.2R3-S1; 18.2 versions prior to 18.2X75-D12, 18.2X75-D33, 18.2X75-D420, 18.2X75-D60, 18.2X75-D411; 18.3 versions prior to 18.3R1-S5, 18.3R2-S1, 18.3R3; 18.4 versions prior to 18.4R1-S4, 18.4R2-S1, 18.4R3; 19.1 versions prior to 19.1R1-S2, 19.1R2; 19.2 versions prior to 19.2R1-S1, 19.2R2. Una vulnerabilidad de escalada de privilegios en dispositivos Juniper Networks Junos OS configurados con Routing Engines (RE) duales (RE), Virtual Chassis (VC) o clúster de alta disponibilidad puede permitir que un usuario autenticado local poco privilegiado y acceso al shell lleve a cabo modificaciones de la configuración no autorizadas. Este problema no afecta al dispositivo con Junos OS con una única configuración de RE o independiente. • https://kb.juniper.net/JSA11010 • CWE-264: Permissions, Privileges, and Access Controls CWE-367: Time-of-check Time-of-use (TOCTOU) Race Condition •

CVSS: 5.3EPSS: 0%CPEs: 222EXPL: 0

Juniper Networks Junos OS uses the 128.0.0.0/2 subnet for internal communications between the RE and PFEs. It was discovered that packets utilizing these IP addresses may egress an EX4300 switch, leaking configuration information such as heartbeats, kernel versions, etc. out to the Internet, leading to an information exposure vulnerability. This issue affects Juniper Networks Junos OS: 14.1X53 versions prior to 14.1X53-D53 on EX4300; 15.1 versions prior to 15.1R7-S6 on EX4300; 15.1X49 versions prior to 15.1X49-D200, 15.1X49-D210 on EX4300; 16.1 versions prior to 16.1R7-S7 on EX4300; 17.1 versions prior to 17.1R2-S11, 17.1R3-S2 on EX4300; 17.2 versions prior to 17.2R3-S3 on EX4300; 17.3 versions prior to 17.3R2-S5, 17.3R3-S7 on EX4300; 17.4 versions prior to 17.4R2-S9, 17.4R3 on EX4300; 18.1 versions prior to 18.1R3-S8 on EX4300; 18.2 versions prior to 18.2R3-S2 on EX4300; 18.3 versions prior to 18.3R2-S3, 18.3R3, 18.3R3-S1 on EX4300; 18.4 versions prior to 18.4R1-S5, 18.4R2-S3, 18.4R3 on EX4300; 19.1 versions prior to 19.1R1-S4, 19.1R2 on EX4300; 19.2 versions prior to 19.2R1-S4, 19.2R2 on EX4300; 19.3 versions prior to 19.3R1-S1, 19.3R2 on EX4300. Juniper Networks Junos OS usa la subred 128.0.0.0/2 para las comunicaciones internas entre RE y PFE. Se detectó que los paquetes que utilizan estas direcciones IP pueden salir de un switch EX4300 y filtrar información de configuración tal como heartbeats, versiones del kernel, etc. hacia la Internet, conllevando una vulnerabilidad de exposición de información. • https://kb.juniper.net/JSA11008 • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •