CVSS: 7.5EPSS: 0%CPEs: 23EXPL: 0

For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5, a weakness in validation of input exists that allows an attacker to alter licenses assigned to the system nodes by sending specially crafted messages to the CLS web service. Para el componente Central Licensing Server utilizado en los productos ABB Ability™ System 800xA y las extensiones del sistema relacionadas, versiones 5.1, 6.0 y 6.1, Compact HMI versiones 5.1 y 6.0, Control Builder Safe 1.0, 1.1 y 2.0, Symphony Plus -S+ Operations 3.0 a 3. 2 Symphony Plus -S+ Engineering 1.1 a 2.2, Composer Harmony 5.1, 6.0 y 6.1, Melody Composer 5.3, 6.1/6.2 y SPE para Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 y 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1. 3 y 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 y 6.1, Composer CTK 6.1 y 6.2, AdvaBuild 3.7 SP1 y SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 y 2.2, Knowledge Manager 8.0, 9.0 y 9. 1, Manufacturing Operations Management 1812 y 1909, ABB AbilityTM SCADAvantage versiones 5.1 a 5.6.5, existe una debilidad en la validación de la entrada que permite a un atacante alterar las licencias asignadas a los nodos del sistema enviando mensajes especialmente diseñados al servicio web CLS • https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230&LanguageCode=en&DocumentPartId=&Action=Launch https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231&LanguageCode=en&DocumentPartId=&Action=Launch https://search.abb.com/library/Download.aspx?DocumentID=3CCA2020-003309&LanguageCode=en&DocumentPartId=&Action=Launch • CWE-20: Improper Input Validation •

CVSS: 7.5EPSS: 0%CPEs: 23EXPL: 0

For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5, a weakness in validation of input exists that allows an attacker to block license handling by sending specially crafted messages to the CLS web service. Para el componente Central Licensing Server utilizado en los productos ABB Ability™ System 800xA y las extensiones del sistema relacionadas, versiones 5.1, 6.0 y 6.1, Compact HMI versiones 5.1 y 6.0, Control Builder Safe 1.0, 1.1 y 2.0, Symphony Plus -S+ Operations 3.0 a 3. 2 Symphony Plus -S+ Engineering 1.1 a 2.2, Composer Harmony 5.1, 6.0 y 6.1, Melody Composer 5.3, 6.1/6.2 y SPE para Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 y 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1. 3 y 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 y 6.1, Composer CTK 6.1 y 6.2, AdvaBuild 3.7 SP1 y SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 y 2.2, Knowledge Manager 8.0, 9.0 y 9. 1, Manufacturing Operations Management 1812 y 1909, ABB AbilityTM SCADAvantage versiones 5.1 a 5.6.5, existe una debilidad en la validación de la entrada que permite a un atacante bloquear la gestión de licencias enviando mensajes especialmente diseñados al servicio web CLS • https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230&LanguageCode=en&DocumentPartId=&Action=Launch https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231&LanguageCode=en&DocumentPartId=&Action=Launch https://search.abb.com/library/Download.aspx?DocumentID=3CCA2020-003309&LanguageCode=en&DocumentPartId=&Action=Launch • CWE-20: Improper Input Validation •

CVSS: 9.8EPSS: 1%CPEs: 22EXPL: 0

For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5. an XML External Entity Injection vulnerability exists that allows an attacker to read or call arbitrary files from the license server and/or from the network and also block the license handling. Para el componente Central Licensing Server utilizado en los productos ABB Ability™ System 800xA y las extensiones del sistema relacionadas, versiones 5.1, 6.0 y 6.1, Compact HMI versiones 5.1 y 6.0, Control Builder Safe 1.0, 1.1 y 2.0, Symphony Plus -S+ Operations 3.0 a 3. 2 Symphony Plus -S+ Engineering 1.1 a 2.2, Composer Harmony 5.1, 6.0 y 6.1, Melody Composer 5.3, 6.1/6.2 y SPE para Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 y 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1. 3 y 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 y 6.1, Composer CTK 6.1 y 6.2, AdvaBuild 3.7 SP1 y SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 y 2.2, Knowledge Manager 8.0, 9.0 y 9. 1, Manufacturing Operations Management 1812 y 1909, ABB AbilityTM SCADAvantage versiones 5.1 a 5.6.5. existe una vulnerabilidad de Inyección de Entidades Externas XML que permite a un atacante leer o llamar archivos arbitrarios desde el servidor de licencias y/o desde la red y también bloquear el manejo de licencias • https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230&LanguageCode=en&DocumentPartId=&Action=Launch https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231&LanguageCode=en&DocumentPartId=&Action=Launch https://search.abb.com/library/Download.aspx?DocumentID=3CCA2020-003309&LanguageCode=en&DocumentPartId=&Action=Launch • CWE-91: XML Injection (aka Blind XPath Injection) •

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

Insufficient folder permissions used by system functions in ABB System 800xA Base (version 6.1 and earlier) allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploit the vulnerabilities could escalate his/her privileges, cause system functions to stop and to corrupt user applications. Los permisos de carpeta insuficientes usados por las funciones del sistema en ABB System 800xA Base (versiones 6.1 y anteriores), permiten a usuarios pocos privilegiados leer, modificar, añadir y eliminar archivos de sistema y de aplicación. Un atacante autenticado que explote con éxito las vulnerabilidades podría escalar sus privilegios, causar que las funcionalidades del sistema se detengan y corromper las aplicaciones de los usuarios. • https://search.abb.com/library/Download.aspx?DocumentID=2PAA121106&LanguageCode=en&DocumentPartId=&Action=Launch • CWE-732: Incorrect Permission Assignment for Critical Resource •

CVSS: 8.8EPSS: 0%CPEs: 3EXPL: 0

The installations for ABB System 800xA Information Manager versions 5.1, 6.0 to 6.0.3.2 and 6.1 wrongly contain an auxiliary component. An attacker is able to use this for an XSS-like attack to an authenticated local user, which might lead to execution of arbitrary code. Las instalaciones de ABB System 800xA Information Manager versiones 5.1, versiones 6.0 hasta 6.0.3.2 y versión 6.1, contienen incorrectamente un componente auxiliar. Un atacante puede usar esto para un ataque de tipo XSS hacia un usuario local autenticado, lo que podría conllevar a una ejecución de código arbitrario. • https://search.abb.com/library/Download.aspx?DocumentID=2PAA121232&LanguageCode=en&DocumentPartId=&Action=Launch • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-489: Active Debug Code •