CVSS: 5.5EPSS: 0%CPEs: 1EXPL: 0

Delta Industrial Automation CNCSoft, CNCSoft ScreenEditor Version 1.00.88 and prior. Multiple out-of-bounds read vulnerabilities may be exploited, allowing information disclosure due to a lack of user input validation for processing specially crafted project files. Delta Industrial Automation CNCSoft, CNCSoft ScreenEditor versión 1.00.88 y anteriores. Se pueden aprovechar múltiples vulnerabilidades de lectura fuera de límites, lo que permite la divulgación de información debido a la falta de comprobación de entrada del usuario para procesar archivos de proyectos especialmente creados. This vulnerability allows remote attackers to disclose sensitive information on vulnerable installations of Delta Industrial Automation CNCSoft ScreenEditor. • http://www.securityfocus.com/bid/107989 https://ics-cert.us-cert.gov/advisories/ICSA-19-106-01 https://www.zerodayinitiative.com/advisories/ZDI-19-406 https://www.zerodayinitiative.com/advisories/ZDI-19-407 https://www.zerodayinitiative.com/advisories/ZDI-19-409 https://www.zerodayinitiative.com/advisories/ZDI-19-411 https://www.zerodayinitiative.com/advisories/ZDI-19-412 https://www.zerodayinitiative.com/advisories/ZDI-19-413 https://www.zerodayinitiative.com/advisories/ZDI-19-414 https:&#x • CWE-125: Out-of-bounds Read •

CVSS: 7.8EPSS: 7%CPEs: 1EXPL: 0

Delta Industrial Automation CNCSoft, CNCSoft ScreenEditor Version 1.00.88 and prior. Multiple stack-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, allowing an attacker to remotely execute arbitrary code. This may occur because CNCSoft lacks user input validation before copying data from project files onto the stack. Delta Industrial Automation CNCSoft, CNCSoft ScreenEditor versión 1.00.88 y anteriores. Se pueden aprovechar múltiples vulnerabilidades de desbordamiento de búfer en la región stack de la memoria al procesar archivos de proyecto especialmente creados, lo que permite a un atacante ejecutar código arbitrario de forma remota. • http://www.securityfocus.com/bid/107989 https://ics-cert.us-cert.gov/advisories/ICSA-19-106-01 https://www.zerodayinitiative.com/advisories/ZDI-19-399 https://www.zerodayinitiative.com/advisories/ZDI-19-400 https://www.zerodayinitiative.com/advisories/ZDI-19-401 https://www.zerodayinitiative.com/advisories/ZDI-19-402 https://www.zerodayinitiative.com/advisories/ZDI-19-403 https://www.zerodayinitiative.com/advisories/ZDI-19-404 https://www.zerodayinitiative.com/advisories/ZDI-19-410 https:&#x • CWE-121: Stack-based Buffer Overflow CWE-787: Out-of-bounds Write •

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

Delta Industrial Automation CNCSoft, CNCSoft ScreenEditor Version 1.00.88 and prior. Multiple heap-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, allowing an attacker to remotely execute arbitrary code. There is a lack of user input validation before copying data from project files onto the heap. Delta Industrial Automation CNCSoft, CNCSoft ScreenEditor versión 1.00.88 y anteriores. Se pueden aprovechar múltiples vulnerabilidades de desbordamiento de búfer en la región heap de la memoria, mediante el procesamiento de archivos de proyecto especialmente creados, lo que permite a un atacante ejecutar código arbitrario de forma remota. • http://www.securityfocus.com/bid/107989 https://ics-cert.us-cert.gov/advisories/ICSA-19-106-01 https://www.zerodayinitiative.com/advisories/ZDI-19-405 https://www.zerodayinitiative.com/advisories/ZDI-19-408 • CWE-122: Heap-based Buffer Overflow CWE-787: Out-of-bounds Write •

CVSS: 9.3EPSS: 1%CPEs: 2EXPL: 0

CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54 has multiple stack-based buffer overflow vulnerabilities that could cause the software to crash due to lacking user input validation before copying data from project files onto the stack. Which may allow an attacker to gain remote code execution with administrator privileges if exploited. CNCSoft en versiones 1.00.83 y anteriores con ScreenEditor 1.00.54 tiene múltiples vulnerabilidades de desbordamiento de búfer basado en pila que podría provocar el cierre inesperado del software debido a la falta de validación de entradas de usuario antes de copiar los datos del los archivos de proyecto a la pila. Esto puede permitir a un atacante ejecutar código remotamente con privilegios de administrador si se explota. This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of Delta Industrial Automation CNCSoft ScreenEditor. • http://www.securityfocus.com/bid/105032 https://ics-cert.us-cert.gov/advisories/ICSA-18-219-01 • CWE-121: Stack-based Buffer Overflow CWE-787: Out-of-bounds Write •

CVSS: 8.1EPSS: 0%CPEs: 2EXPL: 0

CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54 has two out-of-bounds read vulnerabilities could cause the software to crash due to lacking user input validation for processing project files. Which may allow an attacker to gain remote code execution with administrator privileges if exploited. CNCSoft en versiones 1.00.83 y anteriores con ScreenEditor 1.00.54 tiene dos vulnerabilidades de lectura fuera de límites que pueden causar que el software se cierre de manera inesperada debido a la falta de validación de entrada de datos del usuario para procesar los archivos de proyecto. Esto puede permitir a un atacante ejecutar código remotamente con privilegios de administrador si se explota. This vulnerability allows remote attackers to disclose sensitive information on vulnerable installations of Delta Industrial Automation CNCSoft ScreenEditor. • http://www.securityfocus.com/bid/105032 https://ics-cert.us-cert.gov/advisories/ICSA-18-219-01 • CWE-125: Out-of-bounds Read •