CVSS: 7.2EPSS: 0%CPEs: 190EXPL: 0

Insufficient compartmentalization in HECI subsystem for the Intel(R) SPS before versions SPS_E5_04.01.04.516.0, SPS_E5_04.04.04.033.0, SPS_E5_04.04.03.281.0, SPS_E5_03.01.03.116.0, SPS_E3_05.01.04.309.0, SPS_02.04.00.101.0, SPS_SoC-A_05.00.03.114.0, SPS_SoC-X_04.00.04.326.0, SPS_SoC-X_03.00.03.117.0, IGN_E5_91.00.00.167.0, SPS_PHI_03.01.03.078.0 may allow an authenticated user to potentially enable escalation of privilege via physical access. Una Compartimentación no suficiente en el subsistema HECI para el SPS de Intel(R) versiones a SPS_E5_04.01.04.516.0, SPS_E5_04.04.04.03.0, SPS_E5_04.04.03.281.0, SPS_E5_03.01.03.116.0, SPS_E3_05.01.04.309.0, SPS_02.04.00.101. 0, SPS_SoC-A_05.00.03.114.0, SPS_SoC-X_04.00.04.326.0, SPS_SoC-X_03.00.03.117.0, IGN_E5_91.00.00.167.0, SPS_PHI_03.01.03.078.0 pueden permitir a un usuario autenticado habilitar potencialmente una escalada de privilegios por medio del acceso físico • https://security.netapp.com/advisory/ntap-20220210-0005 https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00470.html •

CVSS: 4.4EPSS: 0%CPEs: 333EXPL: 0

Out of bound read in a subsystem in the Intel(R) CSME versions before 12.0.81, 13.0.47, 13.30.17, 14.1.53 and 14.5.32 may allow a privileged user to potentially enable information disclosure via local access. Una lectura fuera de límites de un subsistema en Intel® CSME versiones anteriores a 12.0.81, 13.0.47, 13.30.17, 14.1.53 y 14.5.32 puede permitir a un usuario privilegiado habilitar potencialmente una divulgación de información por medio de un acceso local • https://cert-portal.siemens.com/productcert/pdf/ssa-309571.pdf https://security.netapp.com/advisory/ntap-20210611-0004 https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00459.html • CWE-125: Out-of-bounds Read •

CVSS: 6.7EPSS: 0%CPEs: 576EXPL: 0

Improper buffer restrictions in a subsystem in the Intel(R) CSME versions before 11.8.86, 11.12.86, 11.22.86, 12.0.81, 13.0.47, 13.30.17, 14.1.53, 14.5.32 and 15.0.22 may allow a privileged user to potentially enable escalation of privilege via local access. Unas restricciones de búfer inapropiadas en un subsistema en Intel® CSME versiones anteriores a 11.8.86, 11.12.86, 11.22.86, 12.0.81, 13.0.47, 13.30.17, 14.1.53, 14.5.32 y 15.0.22 pueden permitir a un usuario privilegiado habilitar potencialmente una escalada de privilegios por medio de un acceso local • https://cert-portal.siemens.com/productcert/pdf/ssa-309571.pdf https://security.netapp.com/advisory/ntap-20210611-0004 https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00459.html • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •

CVSS: 4.4EPSS: 0%CPEs: 618EXPL: 0

Improper initialization in a subsystem in the Intel(R) CSME versions before 11.8.86, 11.12.86, 11.22.86, 12.0.81, 13.0.47, 13.30.17, 14.1.53, 14.5.32, 13.50.11 and 15.0.22 may allow a privileged user to potentially enable information disclosure via local access. Una inicialización inapropiada en un subsistema en Intel® CSME versiones anteriores a 11.8.86, 11.12.86, 11.22.86, 12.0.81, 13.0.47, 13.30.17, 14.1.53, 14.5.32, 13.50.11 y 15.0.22 puede habilitar a un usuario privilegiado para permitir potencialmente una divulgación de información por medio de un acceso local • https://cert-portal.siemens.com/productcert/pdf/ssa-309571.pdf https://security.netapp.com/advisory/ntap-20210611-0004 https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00459.html • CWE-665: Improper Initialization •