Page 3 of 13 results (0.007 seconds)

CVSS: 9.8EPSS: 0%CPEs: 11EXPL: 0

KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions are vulnerable to a stack-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and remotely execute code. KEPServerEX: versiones v6.0 hasta v6.9, ThingWorx Kepware Server: versiones v6.8 y v6.9, ThingWorx Industrial Connectivity: Todas las versiones, OPC-Aggregator: Todas las versiones, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: versiones v7.68.804 y v7.66, Software Toolbox TOP Server: Todas las versiones 6.x, son vulnerables a un desbordamiento de búfer en la región stack de la memoria. Abrir un mensaje OPC UA específicamente diseñado podría permitir a un atacante bloquear el servidor y ejecutar código de remotamente • https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02 • CWE-121: Stack-based Buffer Overflow CWE-787: Out-of-bounds Write •

CVSS: 9.1EPSS: 1%CPEs: 11EXPL: 0

KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data. KEPServerEX: versiones v6.0 hasta v6.9, ThingWorx Kepware Server: versiones v6.8 y v6.9, ThingWorx Industrial Connectivity: Todas las versiones, OPC-Aggregator: Todas las versiones, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: versiones v7.68.804 y v7.66, Software Toolbox TOP Server: Todas las versiones 6.x son vulnerables a un desbordamiento de búfer en la región heap de la memoria. Abrir un mensaje OPC UA específicamente diseñado podría permitir a un atacante bloquear el servidor y potencialmente filtrar datos • https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02 • CWE-122: Heap-based Buffer Overflow CWE-787: Out-of-bounds Write •

CVSS: 9.1EPSS: 1%CPEs: 11EXPL: 0

KEPServerEX v6.0 to v6.9, ThingWorx Kepware Server v6.8 and v6.9, ThingWorx Industrial Connectivity (all versions), OPC-Aggregator (all versions), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server v7.68.804 and v7.66, and Software Toolbox TOP Server all 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data. KEPServerEX versiones v6.0 hasta v6.9, ThingWorx Kepware Server versiones v6.8 y v6.9, ThingWorx Industrial Connectivity (todas las versiones), OPC-Aggregator (todas las versiones), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server versiones v7.68.804 y v7.66, y Software Toolbox TOP Server, todas las versiones 6.x, son vulnerables a un desbordamiento del búfer en la región heap de la memoria. Abrir un mensaje OPC UA específicamente diseñado podría permitir a un atacante bloquear el servidor y potencialmente filtrar datos • https://us-cert.cisa.gov/ics/advisories/icsa-20-352-02 • CWE-416: Use After Free CWE-787: Out-of-bounds Write •