CVE-2016-9343
https://notcve.org/view.php?id=CVE-2016-9343
An issue was discovered in Rockwell Automation Logix5000 Programmable Automation Controller FRN 16.00 through 21.00 (excluding all firmware versions prior to FRN 16.00, which are not affected). By sending malformed common industrial protocol (CIP) packet, an attacker may be able to overflow a stack-based buffer and execute code on the controller or initiate a nonrecoverable fault resulting in a denial of service. Ha sido descubierto un problema en Rockwell Automation Logix5000 Programmable Automation Controller FRN 16.00 a 21.00 (excluyendo todas las versiones de firmware anteriores a FRN 16.00, que no se ven afectadas). Al enviar un paquete de protocolo industrial común (CIP) malformado, un atacante puede realizar un desbordamiento de búfer basado en pila y ejecutar código en el controlador o iniciar un fallo irrecuperable que da como resultado una denegación de servicio. • http://www.securityfocus.com/bid/95304 https://ics-cert.us-cert.gov/advisories/ICSA-16-343-05 • CWE-787: Out-of-bounds Write •
CVE-2016-2279 – Rockwell Scada System 27.011 - Cross-Site Scripting
https://notcve.org/view.php?id=CVE-2016-2279
Cross-site scripting (XSS) vulnerability in the web server in Rockwell Automation Allen-Bradley CompactLogix 1769-L* before 28.011+ allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. Vulnerabilidad de XSS en el servidor web en Rockwell Automation Allen-Bradley CompactLogix 1769-L* en versiones anteriores a 28.011+ permite a atacantes remotos inyectar secuencias de comandos web o HTML arbitrarios a través de vectores no especificados. Rockwell Scada System version 27.011 suffers from a cross site scripting vulnerability. • https://www.exploit-db.com/exploits/44626 http://www.securitytracker.com/id/1035190 https://ics-cert.us-cert.gov/advisories/ICSA-16-061-02 • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •
CVE-2012-6442
https://notcve.org/view.php?id=CVE-2012-6442
Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400 allow remote attackers to cause a denial of service (control and communication outage) via a CIP message that specifies a reset. Los productos Rockwell Automation EtherNet/IP: 1756-ENBT, 1756-EWEB, 1768-ENBT, y los módulos de comunicación 1768-EWEB; CompactLogix L32E y controladores L35E; adaptador 1788-ENBT FLEXLogix; adaptador 1794-AENTR FLEX I/O EtherNet/IP; ControlLogix 18 y anteriores; CompactLogix 18 y anteriores; GuardLogix 18 y anteriores; SoftLogix 18 y anteriores; controladores CompactLogix 19 y anteriores; controladores SoftLogix 19 y anteriores; controladores ControlLogix 20 y anteriores; controladores GuardLogix 20 y anteriores; y MicroLogix 1100 y 1400 permiten a atacantes remotos causar una denegación de servicio (control y corte de la comunicación) a través de un mensaje CIP que especifica un reinicio. • http://www.us-cert.gov/control_systems/pdf/ICSA-13-011-03.pdf https://tools.cisco.com/security/center/viewAlert.x?alertId=27862 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •