CVE-2013-2806
https://notcve.org/view.php?id=CVE-2013-2806
Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the “End of Current Record” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to a specifically oversized value, the service will calculate an undersized value for the “Total Record Size.” Then the service will calculate an incorrect value for the “End of Current Record” field causing access violations that lead to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation security advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599 El software RSLinx Enterprise de Rockwell Automation (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1 y CPR9-SR6 no maneja la entrada correctamente y da como resultado un error lógico si calcula un valor incorrecto para el campo “End of Current Record”. • https://ics-cert.us-cert.gov/advisories/ICSA-13-095-02 • CWE-190: Integer Overflow or Wraparound •
CVE-2013-2807
https://notcve.org/view.php?id=CVE-2013-2807
Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the “Total Record Size” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to a specifically oversized value, the service will calculate an undersized value for the “Total Record Size” that will cause an out-of-bounds read access violation that leads to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation Security Advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599 El software RSLinx Enterprise de Rockwell Automation (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1 y CPR9-SR6 no maneja la entrada correctamente y da como resultado un error lógico si calcula un valor incorrecto para el campo “Total Record Size”. Al enviar un datagrama al servicio a través del puerto 4444 / UDP con el campo "“Record Data Size" modificado a un valor específicamente sobredimensionado, el servicio calculará un valor de tamaño inferior al "Tamaño de registro total" que causará un fuera de los límites violación de acceso de lectura que conduce a un bloqueo del servicio. • https://ics-cert.us-cert.gov/advisories/ICSA-13-095-02 • CWE-125: Out-of-bounds Read CWE-190: Integer Overflow or Wraparound •
CVE-2018-14829
https://notcve.org/view.php?id=CVE-2018-14829
Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. This vulnerability may allow a remote threat actor to intentionally send a malformed CIP packet to Port 44818, causing the software application to stop responding and crash. This vulnerability also has the potential to exploit a buffer overflow condition, which may allow the threat actor to remotely execute arbitrary code. Rockwell Automation RSLinx Classic en versiones 4.00.01 y anteriores. Esta vulnerabilidad podría permitir que un actor de amenaza remoto envíe de forma intencional un paquete CIP mal formado al puerto 44818, lo que provoca que la aplicación deje de responder y se cierre inesperadamente. • https://ics-cert.us-cert.gov/advisories/ICSA-18-263-02 https://www.tenable.com/security/research/tra-2018-26 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer CWE-121: Stack-based Buffer Overflow •
CVE-2018-14827
https://notcve.org/view.php?id=CVE-2018-14827
Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. A remote, unauthenticated threat actor may intentionally send specially crafted Ethernet/IP packets to Port 44818, causing the software application to stop responding and crash. The user must restart the software to regain functionality. Rockwell Automation RSLinx Classic en versiones 4.00.01 y anteriores. Un actor de amenaza remoto no autenticado podría enviar de forma intencionada paquetes Ethernet/IP al puerto 44818, lo que provoca que la aplicación del software deje de responder y se cierre inesperadamente. • https://ics-cert.us-cert.gov/advisories/ICSA-18-263-02 • CWE-400: Uncontrolled Resource Consumption •
CVE-2018-14821
https://notcve.org/view.php?id=CVE-2018-14821
Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. This vulnerability may allow a remote, unauthenticated threat actor to intentionally send a malformed CIP packet to Port 44818, causing the RSLinx Classic application to terminate. The user will need to manually restart the software to regain functionality. Rockwell Automation RSLinx Classic en versiones 4.00.01 y anteriores. Esta vulnerabilidad podría permitir que un actor de amenaza remoto no autenticado envíe de forma intencional un paquete CIP mal formado al puerto 44818, lo que provoca que la aplicación RSLinx Classic se termine. • https://ics-cert.us-cert.gov/advisories/ICSA-18-263-02 https://www.tenable.com/security/research/tra-2018-26 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer CWE-122: Heap-based Buffer Overflow •