Page 3 of 28 results (0.003 seconds)

CVSS: 8.6EPSS: 0%CPEs: 2EXPL: 0

11 Dec 2020 — A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure™ Control Expert (all versions) and Unity Pro (former name of EcoStruxure™ Control Expert) (all versions), that could cause a crash of the software or unexpected code execution when opening a malicious file in EcoStruxure™ Control Expert software. Una CWE-123: Se presenta una vulnerabilidad de Condición Write-what-where en EcoStruxure™ Control Expert (todas las versiones) y Unity Pro (nombre anterior de EcoStruxure™ Control Expert) (to... • https://www.se.com/ww/en/download/document/SEVD-2020-343-01 • CWE-123: Write-what-where Condition •

CVSS: 7.5EPSS: 0%CPEs: 1EXPL: 1

19 Nov 2020 — A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request over Modbus. CWE-120: Se presenta una vulnerabilidad de Copia del Búfer sin Comprobar el Tamaño de la Entrada ("Classic Buffer Overflow") en el Simulador de PLC en EcoStruxureª Control Expert (... • https://www.se.com/ww/en/download/document/SEVD-2020-315-07 • CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') •

CVSS: 7.5EPSS: 0%CPEs: 1EXPL: 0

19 Nov 2020 — A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request over Modbus. CWE-754: Se presenta una vulnerabilidad Comprobación Inapropiada de Condiciones Inusuales o Excepcionales en el Simulador de PLC en EcoStruxureª Control Expert (ahora Unity Pro) (todas las versiones... • https://www.se.com/ww/en/download/document/SEVD-2020-315-07 • CWE-754: Improper Check for Unusual or Exceptional Conditions •

CVSS: 8.8EPSS: 0%CPEs: 1EXPL: 0

19 Nov 2020 — A CWE-494: Download of Code Without Integrity Check vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when sending specially crafted requests over Modbus. CWE-494: Se presenta una vulnerabilidad Descarga de Código Sin Comprobación de Integridad en el Simulador de PLC en EcoStruxureª Control Expert (ahora Unity Pro) (todas las versiones) que podría causar la ejecución de comandos no autorizados cuando se envía p... • https://www.se.com/ww/en/download/document/SEVD-2020-315-07 • CWE-494: Download of Code Without Integrity Check •

CVSS: 9.8EPSS: 1%CPEs: 1EXPL: 0

19 Nov 2020 — A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when a brute force attack is done over Modbus. CWE-307: Se presenta una vulnerabilidad de Restricción Inapropiada de Intentos de Autenticación Excesivos en el Simulador de PLC en EcoStruxureª Control Expert (ahora Unity Pro) (todas las versiones) que podría causar la ejecución no autorizada de ... • https://www.se.com/ww/en/download/document/SEVD-2020-315-07 • CWE-307: Improper Restriction of Excessive Authentication Attempts •

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

19 Nov 2020 — A CWE-863: Incorrect Authorization vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause bypass of authentication when overwriting memory using a debugger. CWE-863: Se presenta una vulnerabilidad Autorización Incorrecta en Simulador de PLC en EcoStruxureª Control Expert (ahora Unity Pro) (todas las versiones) que podría causar una omisión de la autenticación cuando se sobrescribe la memoria usando un depurador • https://www.se.com/ww/en/download/document/SEVD-2020-315-07 • CWE-863: Incorrect Authorization •

CVSS: 9.8EPSS: 0%CPEs: 6EXPL: 0

23 Mar 2020 — A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10), which, if exploited, could allow attackers to transfer malicious code to the controller. Una CWE-74: Una Neutralización Inapropiada de Elementos Especiales en la Salida Usada por un C... • http://www.se.com/ww/en/download/document/SEVD-2020-080-01 • CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') •

CVSS: 7.5EPSS: 0%CPEs: 47EXPL: 0

06 Jan 2020 — Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control Expert and the M340 and M580 controllers. Existe una vulnerabilidad de Autorización Incorrecta en EcoStruxure Control Expert (todas las versiones anteriores a la 14.1 Hot Fix), Unity Pro (todas l... • https://www.se.com/ww/en/download/document/SEVD-2019-344-02 • CWE-863: Incorrect Authorization •