CVE-2023-34391 – Insecure Inherited Permissions
https://notcve.org/view.php?id=CVE-2023-34391
Insecure Inherited Permissions vulnerability in Schweitzer Engineering Laboratories SEL-5033 AcSELerator RTAC Software on Windows allows Leveraging/Manipulating Configuration File Search Paths. See Instruction Manual Appendix A [Cybersecurity] tag dated 20230522 for more details. This issue affects SEL-5033 AcSELerator RTAC Software: before 1.35.151.21000. • https://dragos.com https://selinc.com/support/security-notifications/external-reports • CWE-277: Insecure Inherited Permissions CWE-732: Incorrect Permission Assignment for Critical Resource •
CVE-2023-31175 – Execution with Unnecessary Privileges
https://notcve.org/view.php?id=CVE-2023-31175
An Execution with Unnecessary Privileges vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run system commands with the highest level privilege on the system. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20. • https://selinc.com/support/security-notifications/external-reports https://www.nozominetworks.com/blog • CWE-250: Execution with Unnecessary Privileges CWE-269: Improper Privilege Management •
CVE-2023-31174 – Cross-Site Request Forgery (CSRF)
https://notcve.org/view.php?id=CVE-2023-31174
A Cross-Site Request Forgery (CSRF) vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20. • https://selinc.com/support/security-notifications/external-reports https://www.nozominetworks.com/blog • CWE-352: Cross-Site Request Forgery (CSRF) •
CVE-2023-31173 – Use of Hard-coded Credentials
https://notcve.org/view.php?id=CVE-2023-31173
Use of Hard-coded Credentials vulnerability in Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator on Windows allows Authentication Bypass. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20. • https://selinc.com/support/security-notifications/external-reports https://www.nozominetworks.com/blog • CWE-798: Use of Hard-coded Credentials •
CVE-2023-31172 – Incomplete Filtering of Special Elements
https://notcve.org/view.php?id=CVE-2023-31172
An Incomplete Filtering of Special Elements vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0. • https://selinc.com/support/security-notifications/external-reports https://www.nozominetworks.com/blog • CWE-791: Incomplete Filtering of Special Elements •