Page 3 of 27 results (0.003 seconds)

CVSS: 7.8EPSS: 0%CPEs: 4EXPL: 0

18 Jan 2021 — An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A NULL pointer dereference exists when rendering malformed .DXF and .DWG files. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart). Se detectó un problema en el SDK de dibujos de Open Design Alliance anterior a la versión 2021.11. Existe una derivación de puntero nulo al renderizar archivos .DXF y .DWG malformados. • https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf • CWE-476: NULL Pointer Dereference •

CVSS: 7.8EPSS: 0%CPEs: 4EXPL: 0

18 Jan 2021 — An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A Type Confusion issue exists when rendering malformed .DXF and .DWG files. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart). Se detectó un problema en el SDK de dibujos de Open Design Alliance anterior a la versión 2021.11. Existe un problema de confusión de tipos al renderizar archivos .DXF y .DWG malformados. • https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf • CWE-843: Access of Resource Using Incompatible Type ('Type Confusion') •

CVSS: 7.8EPSS: 1%CPEs: 4EXPL: 0

18 Jan 2021 — An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A stack-based buffer overflow vulnerability exists when the recover operation is run with malformed .DXF and .DWG files. This can allow attackers to cause a crash potentially enabling a denial of service attack (Crash, Exit, or Restart) or possible code execution. Se detectó un problema en Open Design Alliance Drawings SDK versiones anteriores a 2021.11. Se presenta una vulnerabilidad de desbordamiento del búfer en la región s... • https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf • CWE-787: Out-of-bounds Write •

CVSS: 7.8EPSS: 0%CPEs: 5EXPL: 0

10 Dec 2013 — Siemens COMOS before 9.2.0.8.1, 10.0 before 10.0.3.1.40, and 10.1 before 10.1.0.0.2 allows local users to gain database privileges via unspecified vectors. Siemens COMOS anterior a la versión 9.2.0.8.1, 10.0 anterior a 10.0.3.1.40, y 10.1 anterior a la versión 10.1.0.0.2 permite a usuarios locales obtener privilegios en la base de datos a través de vectores sin especificar. • http://secunia.com/advisories/56010 • CWE-264: Permissions, Privileges, and Access Controls •

CVSS: 7.8EPSS: 0%CPEs: 3EXPL: 0

09 Aug 2013 — The client application in Siemens COMOS before 9.1 Update 458, 9.2 before 9.2.0.6.37, and 10.0 before 10.0.3.0.19 allows local users to gain privileges and bypass intended database-operation restrictions by leveraging COMOS project access. La aplicación de cliente en Siemens COMOS anterior a v9.1 Update 458, v9.2 anterior a v9.2.0.6.37, y v10.0 anterior a v 10.0.3.0.19 permite a usuarios locales conseguir privilegios y evitar las restricciones de la base de datos de funcionamiento previstos, aprovechando el... • http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-970879.pdf • CWE-264: Permissions, Privileges, and Access Controls •

CVSS: 7.1EPSS: 0%CPEs: 2EXPL: 0

18 Jun 2013 — Unspecified vulnerability in the client library in Siemens COMOS 9.2 before 9.2.0.6.10 and 10.0 before 10.0.3.0.4 allows local users to obtain unintended write access to the database by leveraging read access. Vulnerabilidad no especificada en la biblioteca de cliente de Siemens COMOS v9.2 anterior a v9.2.0.6.10 y v10.0 anterior a v10.0.3.0.4 permite a usuarios locales obtener acceso de escritura no deseado a la base de datos mediante el aprovechamiento del acceso de lectura. • http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-194865.pdf •

CVSS: 8.8EPSS: 0%CPEs: 3EXPL: 0

16 Aug 2012 — Siemens COMOS before 9.1 Patch 413, 9.2 before Update 03 Patch 023, and 10.0 before Patch 005 allows remote authenticated users to obtain database administrative access via unspecified method calls. Siemens COMOS antes de v9.1 Patch 413, v9.2 antes de Update 03 Patch 023 y v10.0 antes de Patch 005 permite a usuarios remotos autenticados obtener acceso a la base de datos administrativa a través de llamadas a métodos no especificados. • http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-312568.pdf • CWE-264: Permissions, Privileges, and Access Controls •