Page 3 of 16 results (0.009 seconds)

CVSS: 7.5EPSS: 0%CPEs: 17EXPL: 0

A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet module DNP3 variant (All versions < V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). The device engineering mechanism allows an unauthenticated remote user to upload a modified device configuration overwriting access authorization passwords. Se ha identificado una vulnerabilidad en Siemens DIGSI 4 (Todas las versiones anteriores a V4.92), EN100 Ethernet module DNP3 variant (Todas las versiones anteriores a V1.05.00), EN100 Ethernet module IEC 104 variant (Todas las versiones), EN100 Ethernet module IEC 61850 variant (Todas las versiones anteriores a V4.30), EN100 Ethernet module Modbus TCP variant (Todas las versiones), EN100 Ethernet module PROFINET IO variant (Todas las versiones). El mecanismo de ingeniería del dispositivo permite que un usuario remoto no autenticado suba una configuración de dispositivo modificada que sobrescriba las contraseñas de autorización de acceso • https://cert-portal.siemens.com/productcert/pdf/ssa-203306.pdf https://ics-cert.us-cert.gov/advisories/ICSA-18-067-01 • CWE-306: Missing Authentication for Critical Function •

CVSS: 9.0EPSS: 0%CPEs: 2EXPL: 0

A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02; SIPROTEC 7SJ686 : All versions < V 4.87; SIPROTEC 7UT686 : All versions < V 4.02; SIPROTEC 7SD686 : All versions < V 4.05; SIPROTEC 7SJ66 : All versions < V 4.30. Attackers with network access to the device's web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations. A legitimate user must be logged into the web interface for the attack to be successful. Se ha identificado una vulnerabilidad en la variante de Firmware PROFINET IO para los módulos EN100 Ethernet: en todas las versiones anteriores a V1.04.01; la variante de Firmware Modbus TCP para los módulos EN100 Ethernet: en todas las versiones anteriores a V1.11.00; la variante de Firmware v TCP para los módulos EN100 Ethernet: en todas las versiones anteriores a V1.03; la variante de Firmware IEC 104 para los módulos EN100 Ethernet: en todas las versiones anteriores a V1.21 y el módulo EN100 Ethernet incluido en SIPROTEC Merging Unit 6MU80: todas las versiones anteriores a la 1.02.02; SIPROTEC 7SJ686: todas las versiones anteriores a la V 4.87 y SIPROTEC 7UT686: todas las versiones anteriores a la V 4.02 y SIPROTEC 7SD686: todas las versiones anteriores a la V 4.05 y SIPROTEC 7SJ66: todas las versiones anteriores a la V 4.30. Los atacantes que tengan acceso de red a la interfaz web del dispositivo (puerto 80/tcp) podrían omitir la autenticación y realizar ciertas operaciones administrativas. • http://www.securityfocus.com/bid/92745 http://www.securityfocus.com/bid/99471 http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03 https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf • CWE-287: Improper Authentication •

CVSS: 10.0EPSS: 0%CPEs: 2EXPL: 0

A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. Attackers with network access to the device's web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations. Se ha identificado una vulnerabilidad en la variante de Firmware PROFINET IO para los módulos EN100 Ethernet: en todas las versiones anteriores a V1.04.01; la variante de Firmware Modbus TCP para los módulos EN100 Ethernet: en todas las versiones anteriores a V1.11.00; la variante de Firmware v TCP para los módulos EN100 Ethernet: en todas las versiones anteriores a V1.03; la variante de Firmware IEC 104 para los módulos EN100 Ethernet: en todas las versiones anteriores a V1.21 y el módulo EN100 Ethernet incluido en SIPROTEC Merging Unit 6MU80: todas las versiones anteriores a la 1.02.02. Los atacantes que tengan acceso de red a la interfaz web del dispositivo (puerto 80/tcp) podrían omitir la autenticación y realizar ciertas operaciones administrativas. • http://www.securityfocus.com/bid/92747 http://www.securityfocus.com/bid/99471 http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03 https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf • CWE-287: Improper Authentication •

CVSS: 7.8EPSS: 0%CPEs: 2EXPL: 0

A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. Specially crafted packets sent to port 80/tcp could cause the affected device to go into defect mode. Se ha identificado una vulnerabilidad en la variante de Firmware PROFINET IO para los módulos EN100 Ethernet: en todas las versiones anteriores a V1.04.01; la variante de Firmware Modbus TCP para los módulos EN100 Ethernet: en todas las versiones anteriores a V1.11.00; la variante de Firmware v TCP para los módulos EN100 Ethernet: en todas las versiones anteriores a V1.03; la variante de Firmware IEC 104 para los módulos EN100 Ethernet: en todas las versiones anteriores a V1.21 y el módulo EN100 Ethernet incluido en SIPROTEC Merging Unit 6MU80: todas las versiones anteriores a la 1.02.02. El envío de paquetes especialmente manipulados al puerto 80/tcp podrían provocar que el dispositivo afectado entre en modo defect. • http://www.securityfocus.com/bid/92748 http://www.securityfocus.com/bid/99471 http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03 https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf • CWE-399: Resource Management Errors •

CVSS: 5.3EPSS: 0%CPEs: 10EXPL: 0

A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02; SIPROTEC 7SJ686 : All versions < V 4.83; SIPROTEC 7UT686 : All versions < V 4.01; SIPROTEC 7SD686 : All versions < V 4.03; SIPROTEC 7SJ66 : All versions < V 4.20. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained. Se ha identificado una vulnerabilidad en la variante de Firmware PROFINET IO para los módulos EN100 Ethernet: en todas las versiones anteriores a V1.04.01; la variante de Firmware Modbus TCP para los módulos EN100 Ethernet: en todas las versiones anteriores a V1.11.00; la variante de Firmware v TCP para los módulos EN100 Ethernet: en todas las versiones anteriores a V1.03; la variante de Firmware IEC 104 para los módulos EN100 Ethernet: en todas las versiones anteriores a V1.21 y el módulo EN100 Ethernet incluido en SIPROTEC Merging Unit 6MU80: todas las versiones anteriores a la 1.02.02; SIPROTEC 7SJ686: todas las versiones anteriores a la V 4.83; SIPROTEC 7UT686: todas las versiones anteriores a la V 4.01; SIPROTEC 7SD686: todas las versiones anteriores a la V 4.03 y SIPROTEC 7SJ66: todas las versiones anteriores a la V 4.20. El servidor web integrado (puerto 80/tcp) de los dispositivos afectados podría permitir que los atacantes remotos obtengan información sensible del dispositivo si obtienen acceso de red. • http://www.securityfocus.com/bid/90773 http://www.securityfocus.com/bid/99471 http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-547990.pdf https://ics-cert.us-cert.gov/advisories/ICSA-16-140-02 https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03 https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •