CVSS: 7.5EPSS: 0%CPEs: 96EXPL: 0

A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations. • https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf • CWE-672: Operation on a Resource after Expiration or Release •

CVSS: 5.3EPSS: 0%CPEs: 119EXPL: 0

A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7 PLCSIM Advanced (All versions > V2 < V4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Version V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions > V2.5 < V2.9.2), SIMATIC S7-1500 Software Controller (All versions > V2.5 < V21.9), TIM 1531 IRC (incl. SIPLUS NET variants) (Version V2.1). Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once. • https://cert-portal.siemens.com/productcert/pdf/ssa-865327.pdf • CWE-863: Incorrect Authorization •

CVSS: 9.8EPSS: 0%CPEs: 63EXPL: 0

A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINAMICS PERFECT HARMONY GH180 Drives (Drives manufactured before 2021-08-13), SINUMERIK MC (All versions < V6.15), SINUMERIK ONE (All versions < V6.15). Affected devices are vulnerable to a memory protection bypass through a specific operation. • https://cert-portal.siemens.com/productcert/pdf/ssa-434534.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-434535.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-434536.pdf • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •

CVSS: 7.5EPSS: 0%CPEs: 4EXPL: 0

A vulnerability has been identified in SIMATIC ET 200SP Open Controller (incl. SIPLUS variants) (V20.8), SIMATIC S7-1500 Software Controller (V20.8). The web server of the affected products contains a vulnerability that could allow a remote attacker to trigger a denial-of-service condition by sending a specially crafted HTTP request. Se ha identificado una vulnerabilidad en SIMATIC ET 200SP Open Controller (incluyendo variantes SIPLUS) (versión V20.8), SIMATIC S7-1500 Software Controller (versión V20.8).&#xa0;El servidor web de los productos afectados contiene una vulnerabilidad que podría permitir a un atacante remoto desencadenar una condición de denegación de servicio mediante el envío de una petición HTTP especialmente diseñada • https://cert-portal.siemens.com/productcert/pdf/ssa-700697.pdf • CWE-248: Uncaught Exception •

CVSS: 7.2EPSS: 0%CPEs: 44EXPL: 0

A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges. Se ha identificado una vulnerabilidad en SIMATIC Automation Tool (Todas las versiones anteriores a la versión V4 SP2), SIMATIC NET PC Software V14 (Todas las versiones anteriores a la versión V14 SP1 Update 14), SIMATIC NET PC Software V15 (Todas las versiones), SIMATIC NET PC Software V16 (Todas las versiones anteriores a la versión V16 Upd3), SIMATIC PCS neo (Todas las versiones anteriores a la versión V3.0 SP1), SIMATIC ProSave (Todas las versiones anteriores a la versión V17), SIMATIC S7-1500 Software Controller (Todas las versiones anteriores a la versión V21. 8), SIMATIC STEP 7 (Todas las versiones anteriores a la versión V5.6 SP2 HF3), SIMATIC STEP 7 (TIA Portal) V13 (Todas las versiones anteriores a la versión V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (Todas las versiones anteriores a la versión V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (Todas las versiones anteriores a la versión V15. 1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (Todas las versiones anteriores a la versión V16 Update 2), SIMATIC WinCC OA V3.16 (Todas las versiones anteriores a la versión V3.16 P018), SIMATIC WinCC OA V3. 17 (Todas las versiones anteriores a la versión V3.17 P003), SIMATIC WinCC Runtime Advanced (Todas las versiones anteriores a la versión V16 Update 2), SIMATIC WinCC Runtime Professional V13 (Todas las versiones anteriores a la versión V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (Todas las versiones anteriores a la versión V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (Todas las versiones anteriores a la versión V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (Todas las versiones anteriores a la versión V16 Update 2), SIMATIC WinCC V7. 4 (Todas las versiones anteriores a la versión V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (Todas las versiones anteriores a la versión V7.5 SP1 Update 3), SINAMICS STARTER (Todas las versiones anteriores a la versión V5.4 HF2), SINAMICS Startdrive (Todas las versiones anteriores a la versión V16 Update 3), SINEC NMS (Todas las versiones anteriores a la versión V1. 0 SP2), SINEMA Server (Todas las versiones anteriores a la versión V14 SP3), SINUMERIK ONE virtual (Todas las versiones anteriores a la versión V6.14), SINUMERIK Operate (Todas las versiones anteriores a la versión V6.14). Un componente dentro de la aplicación afectada llama regularmente a un binario de ayuda con privilegios de SISTEMA mientras la ruta de llamada no está citada • https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04 • CWE-428: Unquoted Search Path or Element •