CVSS: 9.1EPSS: 0%CPEs: 70EXPL: 0

A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior) Una CWE-287: Se presenta una vulnerabilidad de autenticación inapropiada que podría causar que un atacante cambie arbitrariamente el comportamiento del SAI cuando es filtrada una clave y es usada para cargar firmware malicioso. Producto afectado: Familia de Smart-UPS de APC: Serie SMT (SMT Series ID=18: UPS versiones 09.8 y anteriores / SMT Series ID=1040: UPS versiones 01.2 y anteriores / SMT Series ID=1031: UPS versiones 03.1 y anteriores), SMC Series (SMC Series ID=1005: UPS versiones 14.1 y anteriores / SMC Series ID=1007: UPS versiones 11.0 y anteriores / SMC Series ID=1041: UPS versiones 01.1 y anteriores), SCL Series (SCL Series ID=1030: UPS versiones 02.5 y anteriores / SCL Series ID=1036: UPS versiones 02.5 y anteriores), SMX Series (SMX Series ID=20: UPS versiones 10.2 y anteriores / SMX Series ID=23: UPS versiones 07.0 y anteriores), SRT Series (SRT Series ID=1010/1019/1025: UPS versiones 08.3 y anteriores / SRT Series ID=1024: UPS versiones 01.0 y anteriores / SRT Series ID=1020: UPS versiones 10.4 y anteriores / SRT Series ID=1021: UPS versiones 12.2 y anteriores / SRT Series ID=1001/1013: UPS versiones 05.1 y anteriores / SRT Series ID=1002/1014: UPS versiones a05.2 y anteriores), Familia SmartConnect de APC: Serie SMT (Serie SMT ID=1015: UPS versiones 04.5 y anteriores), Serie SMC (Serie SMC ID=1018: UPS versiones 04.2 y anteriores), Serie SMTL (Serie SMTL ID=1026: UPS versiones 02.9 y anteriores), Serie SCL (Serie SCL ID=1029: UPS versiones 02.5 y anteriores / SCL Series ID=1030: UPS versiones 02.5 y anteriores / SCL Series ID=1036: UPS versiones 02.5 y anteriores / SCL Series ID=1037: UPS versiones 03.1 y anteriores), SMX Series (SMX Series ID=1031: UPS versiones 03.1 y anteriores) • https://www.se.com/ww/en/download/document/SEVD-2022-067-02 • CWE-287: Improper Authentication CWE-345: Insufficient Verification of Data Authenticity •

CVSS: 7.5EPSS: 0%CPEs: 1EXPL: 0

A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior) Una CWE-120: Se presenta una vulnerabilidad de Copia del Búfer sin Comprobar el Tamaño de la Entrada que podría resultar en una denegación de servicio, debido a una falta de comprobación de la longitud de los datos suministrados por el usuario de un mensaje construido recibido en la red. Producto afectado: Interactive Graphical SCADA System Data Collector (dc.exe) (versiones V15.0.0.21320 y anteriores) • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-01 • CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') •

CVSS: 7.5EPSS: 0%CPEs: 2EXPL: 0

A CWE-20: Improper Input Validation vulnerability exists that could cause a Denial of Service when a crafted packet is sent to the controller over network port 1105/TCP. Affected Product: Modicon M218 Logic Controller (V5.1.0.6 and prior) Una CWE-20: Se presenta una vulnerabilidad de Comprobación de Entrada Inapropiada que podría causar una denegación de servicio cuando es enviado un paquete diseñado al controlador a través del puerto de red 1105/TCP. Producto afectado: Modicon M218 Logic Controller (versiones V5.1.0.6 y anteriores) • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-04 • CWE-20: Improper Input Validation •

CVSS: 9.1EPSS: 0%CPEs: 1EXPL: 0

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior) Una CWE-306: Se presenta una vulnerabilidad de Falta de Autenticación para una Función Crítica que podría causar el borrado de archivos arbitrarios en el contexto del usuario que ejecuta IGSS debido a una falta de comprobación de los mensajes de red. Producto afectado: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 y anteriores) • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-01 • CWE-306: Missing Authentication for Critical Function •

CVSS: 7.5EPSS: 0%CPEs: 6EXPL: 0

A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could cause data exfiltration and unauthorized access when accessing a malicious website. Affected Product: spaceLYnk (V2.6.1 and prior), Wiser for KNX (V2.6.1 and prior), fellerLYnk (V2.6.1 and prior) Una CWE-669: Se presenta una vulnerabilidad de Transferencia Incorrecta de Recursos entre Esferas que podría causar una exfiltración de datos y el acceso no autorizado cuando es accedido a un sitio web malicioso. Producto afectado: spaceLYnk (versiones V2.6.1 y anteriores), Wiser for KNX (versiones V2.6.1 y anteriores), fellerLYnk (versiones V2.6.1 y anteriores) • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-01 • CWE-669: Incorrect Resource Transfer Between Spheres •