Page 39 of 208 results (0.002 seconds)

CVSS: 4.4EPSS: 0%CPEs: 41EXPL: 0

In cmdq driver, there is a possible out of bounds read due to an incorrect bounds check. This could lead to local information disclosure with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS05747150; Issue ID: ALPS05747150. En cmdq driver, se presenta una posible lectura fuera de límites debido a una comprobación de límites incorrecta. • https://corp.mediatek.com/product-security-bulletin/February-2022 • CWE-125: Out-of-bounds Read •

CVSS: 7.8EPSS: 0%CPEs: 29EXPL: 0

In system service, there is a possible permission bypass due to a missing permission check. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS06219064; Issue ID: ALPS06219064. En system service, se presenta una posible omisión de permisos debido a una falta de comprobación de permisos. • https://corp.mediatek.com/product-security-bulletin/February-2022 • CWE-862: Missing Authorization •

CVSS: 6.5EPSS: 0%CPEs: 59EXPL: 0

In Bluetooth, there is a possible application crash due to bluetooth flooding a device with LMP_AU_rand packet. This could lead to remote denial of service of bluetooth with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS06198608; Issue ID: ALPS06198608. En Bluetooth, se presenta un posible bloqueo de la aplicación debido a que bluetooth inunda un dispositivo con el paquete LMP_AU_rand. • https://corp.mediatek.com/product-security-bulletin/January-2022 • CWE-772: Missing Release of Resource after Effective Lifetime •

CVSS: 6.5EPSS: 0%CPEs: 30EXPL: 0

In Bluetooth, there is a possible link disconnection due to bluetooth does not properly handle a connection attempt from a host with the same BD address as the currently connected BT host. This could lead to remote denial of service of bluetooth with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS06198578; Issue ID: ALPS06198578. En Bluetooth, se presenta una posible desconexión del enlace debido a que bluetooth no maneja apropiadamente un intento de conexión desde un host con la misma dirección BD que el host BT actualmente conectado. • https://corp.mediatek.com/product-security-bulletin/January-2022 •

CVSS: 6.5EPSS: 0%CPEs: 31EXPL: 0

In Bluetooth, there is a possible application crash due to bluetooth does not properly handle the reception of multiple LMP_host_connection_req. This could lead to remote denial of service of bluetooth with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS06198513; Issue ID: ALPS06198513. En Bluetooth, se presenta un posible bloqueo de la aplicación debido a que bluetooth no maneja apropiadamente la recepción de múltiples LMP_host_connection_req. • https://corp.mediatek.com/product-security-bulletin/January-2022 •