Page 4 of 44 results (0.007 seconds)

CVSS: 6.5EPSS: 0%CPEs: 6EXPL: 0

A vulnerability in the Brocade Fabric OS before Brocade Fabric OS v9.0.1a, v8.2.3, v8.2.0_CBN4, and v7.4.2h could allow an authenticated CLI user to abuse the history command to write arbitrary content to files. Una vulnerabilidad en Brocade Fabric OS antes de Brocade Fabric OS v9.0.1a, v8.2.3, v8.2.0_CBN4 y v7.4.2h podría permitir a un usuario autenticado de la CLI abusar del comando history para escribir contenido arbitrario en archivos • https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1493 •

CVSS: 6.5EPSS: 0%CPEs: 2EXPL: 0

The Web application of Brocade Fabric OS before versions Brocade Fabric OS v9.0.1a and v8.2.3a contains debug statements that expose sensitive information to the program's standard output device. An attacker who has compromised the FOS system may utilize this weakness to capture sensitive information, such as user credentials. La aplicación web de Brocade Fabric OS versiones anteriores a Brocade Fabric OS v9.0.1a y v8.2.3a, contiene declaraciones de depuración que exponen información confidencial al dispositivo de salida estándar del programa. Un atacante que haya comprometido el sistema FOS puede usar esta debilidad para capturar información confidencial, como las credenciales de usuarios • https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1494 •

CVSS: 9.8EPSS: 0%CPEs: 4EXPL: 0

Brocade Fabric OS before Brocade Fabric OS v8.2.1c, v8.1.2h, and all versions of Brocade Fabric OS v8.0.x and v7.x contain documented hard-coded credentials, which could allow attackers to gain access to the system. Brocade Fabric OS versiones anteriores a Brocade Fabric OS versiones v8.2.1c, v8.1.2h, y todas las versiones de Brocade Fabric OS v8.0.x y v7.x contienen credenciales documentadas embebidas, que podrían permitir a los atacantes conseguir acceso al sistema • https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1722 • CWE-798: Use of Hard-coded Credentials •

CVSS: 6.8EPSS: 0%CPEs: 2EXPL: 0

A vulnerability in Brocade Fabric OS versions before Brocade Fabric OS v8.0.1b, v7.4.1d could allow an authenticated attacker within the restricted shell environment (rbash) as either the “user” or “factory” account, to read the contents of any file on the filesystem utilizing one of a few available binaries. Una vulnerabilidad en Brocade Fabric OS versiones anteriores a Brocade Fabric OS v8.0.1b, v7.4.1d podría permitir a un atacante autenticado dentro del entorno de shell restringido (rbash) como cuenta "user" o "factory", leer el contenido de cualquier archivo del sistema de archivos utilizando uno de los pocos binarios disponibles • https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1721 •

CVSS: 7.8EPSS: 0%CPEs: 4EXPL: 0

The command ipfilter in Brocade Fabric OS before Brocade Fabric OS v.9.0.1a, v8.2.3, and v8.2.0_CBN4, and v7.4.2h uses unsafe string function to process user input. Authenticated attackers can abuse this vulnerability to exploit stack-based buffer overflows, allowing execution of arbitrary code as the root user account. El comando ipfilter en Brocade Fabric OS versiones anteriores a Brocade Fabric OS v.9.0.1a, v8.2.3, y v8.2.0_CBN4, y v7.4.2h, usa una función de cadena no segura para procesar la entrada del usuario. Unos atacantes autenticados pueden abusar de esta vulnerabilidad para explotar unos desbordamientos de búfer en la región stack de la memoria, permitiendo una ejecución de código arbitrario como la cuenta de usuario root. • https://security.netapp.com/advisory/ntap-20210819-0002 https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1492 • CWE-787: Out-of-bounds Write •