CVE-2022-22178 – Junos OS: MX and SRX series: Flowd core observed if the SIP ALG is enabled and a specific Session Initiation Protocol (SIP) packet is received
https://notcve.org/view.php?id=CVE-2022-22178
19 Jan 2022 — A Stack-based Buffer Overflow vulnerability in the flow processing daemon (flowd) of Juniper Networks Junos OS on MX Series and SRX series allows an unauthenticated networked attacker to cause a flowd crash and thereby a Denial of Service (DoS). Continued receipt of these specific packets will cause a sustained Denial of Service condition. This issue can be triggered by a specific Session Initiation Protocol (SIP) invite packet if the SIP ALG is enabled. Due to this, the PIC will be rebooted and all traffic... • https://kb.juniper.net/JSA11284 • CWE-121: Stack-based Buffer Overflow •

CVE-2022-22175 – Junos OS: MX Series and SRX Series: The flowd daemon will crash if the SIP ALG is enabled and specific SIP messages are processed
https://notcve.org/view.php?id=CVE-2022-22175
19 Jan 2022 — An Improper Locking vulnerability in the SIP ALG of Juniper Networks Junos OS on MX Series and SRX Series allows an unauthenticated networked attacker to cause a flowprocessing daemon (flowd) crash and thereby a Denial of Service (DoS). Continued receipt of these specific packets will cause a sustained Denial of Service condition. This issue can occur in a scenario where the SIP ALG is enabled and specific SIP messages are being processed simultaneously. This issue affects: Juniper Networks Junos OS on MX S... • https://kb.juniper.net/JSA11281 • CWE-667: Improper Locking •

CVE-2022-22167 – Junos OS: SRX Series: If no-syn-check is enabled, traffic classified as UNKNOWN gets permitted by pre-id-default-policy
https://notcve.org/view.php?id=CVE-2022-22167
19 Jan 2022 — A traffic classification vulnerability in Juniper Networks Junos OS on the SRX Series Services Gateways may allow an attacker to bypass Juniper Deep Packet Inspection (JDPI) rules and access unauthorized networks or resources, when 'no-syn-check' is enabled on the device. While JDPI correctly classifies out-of-state asymmetric TCP flows as the dynamic-application UNKNOWN, this classification is not provided to the policy module properly and hence traffic continues to use the pre-id-default-policy, which is ... • https://kb.juniper.net/JSA11265 • CWE-863: Incorrect Authorization •

CVE-2022-22153 – SRX Series and MX Series with SPC3: A high percentage of fragments might lead to high latency or packet drops
https://notcve.org/view.php?id=CVE-2022-22153
19 Jan 2022 — An Insufficient Algorithmic Complexity combined with an Allocation of Resources Without Limits or Throttling vulnerability in the flow processing daemon (flowd) of Juniper Networks Junos OS on SRX Series and MX Series with SPC3 allows an unauthenticated network attacker to cause latency in transit packet processing and even packet loss. If transit traffic includes a significant percentage (> 5%) of fragmented packets which need to be reassembled, high latency or packet drops might be observed. This issue af... • https://kb.juniper.net/JSA11261 • CWE-407: Inefficient Algorithmic Complexity CWE-770: Allocation of Resources Without Limits or Throttling •

CVE-2021-31373 – Junos OS: SRX Series: Persistent XSS vulnerability in J-Web
https://notcve.org/view.php?id=CVE-2021-31373
19 Oct 2021 — A persistent Cross-Site Scripting (XSS) vulnerability in Juniper Networks Junos OS on SRX Series, J-Web interface may allow a remote authenticated user to inject persistent and malicious scripts. An attacker can exploit this vulnerability to steal sensitive data and credentials from a web administration session, or hijack another user's active session to perform administrative actions. This issue affects: Juniper Networks Junos OS on SRX Series: 18.2 versions prior to 18.2R3-S8; 18.3 versions prior to 18.3R... • https://kb.juniper.net/JSA11238 • CWE-20: Improper Input Validation CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVE-2021-31364 – Junos OS: SRX Series: The flowd process will crash if log session-close is configured and specific traffic is received
https://notcve.org/view.php?id=CVE-2021-31364
19 Oct 2021 — An Improper Check for Unusual or Exceptional Conditions vulnerability combined with a Race Condition in the flow daemon (flowd) of Juniper Networks Junos OS on SRX300 Series, SRX500 Series, SRX1500, and SRX5000 Series with SPC2 allows an unauthenticated network based attacker sending specific traffic to cause a crash of the flowd/srxpfe process, responsible for traffic forwarding in SRX, which will cause a Denial of Service (DoS). Continued receipt and processing of this specific traffic will create a susta... • https://kb.juniper.net/JSA11226 • CWE-362: Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition') CWE-754: Improper Check for Unusual or Exceptional Conditions •

CVE-2021-0289 – Junos OS: User-defined ARP Policer isn't applied on Aggregated Ethernet (AE) interface until firewall process is restarted
https://notcve.org/view.php?id=CVE-2021-0289
15 Jul 2021 — When user-defined ARP Policer is configured and applied on one or more Aggregated Ethernet (AE) interface units, a Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability between the Device Control Daemon (DCD) and firewall process (dfwd) daemons of Juniper Networks Junos OS allows an attacker to bypass the user-defined ARP Policer. In this particular case the User ARP policer is replaced with default ARP policer. To review the desired ARP Policers and actual state one can run the command "show inte... • https://kb.juniper.net/JSA11191 • CWE-367: Time-of-check Time-of-use (TOCTOU) Race Condition •

CVE-2021-0235 – Junos OS: SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3, vSRX Series: In a multi-tenant environment, a tenant host administrator may configure logical firewall isolation affecting other tenant networks
https://notcve.org/view.php?id=CVE-2021-0235
22 Apr 2021 — On SRX1500, SRX4100, SRX4200, SRX4600, SRX5000 Series with SPC2/SPC3, vSRX Series devices using tenant services on Juniper Networks Junos OS, due to incorrect permission scheme assigned to tenant system administrators, a tenant system administrator may inadvertently send their network traffic to one or more tenants while concurrently modifying the overall device system traffic management, affecting all tenants and the service provider. Further, a tenant may inadvertently receive traffic from another tenant.... • https://kb.juniper.net/JSA11130 • CWE-276: Incorrect Default Permissions •

CVE-2021-0230 – Junos OS: SRX Series: Memory leak when querying Aggregated Ethernet (AE) interface statistics
https://notcve.org/view.php?id=CVE-2021-0230
22 Apr 2021 — On Juniper Networks SRX Series devices with link aggregation (lag) configured, executing any operation that fetches Aggregated Ethernet (AE) interface statistics, including but not limited to SNMP GET requests, causes a slow kernel memory leak. If all the available memory is consumed, the traffic will be impacted and a reboot might be required. The following log can be seen if this issue happens. /kernel: rt_pfe_veto: Memory over consumed. Op 1 err 12, rtsm_id 0:-1, msg type 72 /kernel: rt_pfe_veto: free km... • https://kb.juniper.net/JSA11125 • CWE-400: Uncontrolled Resource Consumption CWE-401: Missing Release of Memory after Effective Lifetime •

CVE-2021-0211 – Junos OS and Junos OS Evolved: Upon receipt of a specific BGP FlowSpec message network traffic may be disrupted.
https://notcve.org/view.php?id=CVE-2021-0211
15 Jan 2021 — An improper check for unusual or exceptional conditions in Juniper Networks Junos OS and Junos OS Evolved Routing Protocol Daemon (RPD) service allows an attacker to send a valid BGP FlowSpec message thereby causing an unexpected change in the route advertisements within the BGP FlowSpec domain leading to disruptions in network traffic causing a Denial of Service (DoS) condition. Continued receipt of these update messages will cause a sustained Denial of Service condition. This issue affects Juniper Network... • https://kb.juniper.net/JSA11101 • CWE-754: Improper Check for Unusual or Exceptional Conditions •